Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Succinylated Jeffamine ED-2003 coated polycarbonate chips for low-cost analytical microarrays
by
Kober, Catharina
, Seidel, Michael
, Bemetz, Jonas
, Meyer, Verena K
, Niessner, Reinhard
in
Analytical chemistry
/ Antibodies
/ Baking
/ Chemiluminescence
/ Chip formation
/ Chips
/ Coatings
/ Cost analysis
/ DNA microarrays
/ Enrofloxacin
/ Immunoassay
/ Immunoassays
/ Laboratory equipment
/ Legionnaires' disease bacterium
/ Mathematical analysis
/ Oligonucleotides
/ Organic chemistry
/ Polycarbonate
/ Proteins
/ Recombinase
/ Regeneration
/ Sheets
/ Shielding
2019
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Succinylated Jeffamine ED-2003 coated polycarbonate chips for low-cost analytical microarrays
by
Kober, Catharina
, Seidel, Michael
, Bemetz, Jonas
, Meyer, Verena K
, Niessner, Reinhard
in
Analytical chemistry
/ Antibodies
/ Baking
/ Chemiluminescence
/ Chip formation
/ Chips
/ Coatings
/ Cost analysis
/ DNA microarrays
/ Enrofloxacin
/ Immunoassay
/ Immunoassays
/ Laboratory equipment
/ Legionnaires' disease bacterium
/ Mathematical analysis
/ Oligonucleotides
/ Organic chemistry
/ Polycarbonate
/ Proteins
/ Recombinase
/ Regeneration
/ Sheets
/ Shielding
2019
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Succinylated Jeffamine ED-2003 coated polycarbonate chips for low-cost analytical microarrays
by
Kober, Catharina
, Seidel, Michael
, Bemetz, Jonas
, Meyer, Verena K
, Niessner, Reinhard
in
Analytical chemistry
/ Antibodies
/ Baking
/ Chemiluminescence
/ Chip formation
/ Chips
/ Coatings
/ Cost analysis
/ DNA microarrays
/ Enrofloxacin
/ Immunoassay
/ Immunoassays
/ Laboratory equipment
/ Legionnaires' disease bacterium
/ Mathematical analysis
/ Oligonucleotides
/ Organic chemistry
/ Polycarbonate
/ Proteins
/ Recombinase
/ Regeneration
/ Sheets
/ Shielding
2019
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Succinylated Jeffamine ED-2003 coated polycarbonate chips for low-cost analytical microarrays
Journal Article
Succinylated Jeffamine ED-2003 coated polycarbonate chips for low-cost analytical microarrays
2019
Request Book From Autostore
and Choose the Collection Method
Overview
Analytical microarrays feature great capabilities for simultaneous detection and quantification of multiple analytes in a single measurement. In this work, we present a rapid and simple method for bulk preparation of microarrays on polycarbonate sheets. Succinylated Jeffamine® ED-2003 was screen printed on polycarbonate sheets to create a polyfunctional shielding layer by baking at 100 °C. After microdispension of capture probes (antibodies, oligonucleotides, or small molecules) in a microarray format, chips were assembled with a flow cell from double-sided tape. It was shown that the shielding layer was firmly coated and suppressed unspecific binding of proteins. Universal applicability was demonstrated by transferring established flow-based chemiluminescence microarray measurement principles from glass slides to polycarbonate chips without loss of analytical performance. Higher chemiluminescence signals could be generated by performing heterogeneous asymmetric recombinase polymerase amplification on polycarbonate chips. Similar results could be shown for sandwich microarray immunoassays. Beyond that, lower inter- and intra-assay variances could be measured for the analysis of Legionella pneumophila Serogroup 1, strain Bellingham-1. Even surface regeneration of indirect competitive immunoassays was possible, achieving a limit of detection of 0.35 ng L−1 for enrofloxacin with polycarbonate microarray chips. Succinylated Jeffamine ED-2003 coated polycarbonate chips have great potential to replace microtiter plates by flow-based chemiluminescence microarrays for rapid analysis. Therefore, it helps analytical microarrays to advance into routine analysis and diagnostics.
This website uses cookies to ensure you get the best experience on our website.