MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Evaluation of visual function within the central 10 degrees using IMOvifa™ 24plus (1-2)
Evaluation of visual function within the central 10 degrees using IMOvifa™ 24plus (1-2)
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Evaluation of visual function within the central 10 degrees using IMOvifa™ 24plus (1-2)
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Evaluation of visual function within the central 10 degrees using IMOvifa™ 24plus (1-2)
Evaluation of visual function within the central 10 degrees using IMOvifa™ 24plus (1-2)

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Evaluation of visual function within the central 10 degrees using IMOvifa™ 24plus (1-2)
Evaluation of visual function within the central 10 degrees using IMOvifa™ 24plus (1-2)
Journal Article

Evaluation of visual function within the central 10 degrees using IMOvifa™ 24plus (1-2)

2025
Request Book From Autostore and Choose the Collection Method
Overview
The IMOvifa™ perimeter with a 24plus (1-2) testing mode has additional measurement points within the central 10 degrees, which may help evaluate the visual field within this area. Here, we comparatively evaluated the IMOvifa™ 24plus (1-2) and HFA 10-2 for the first time. We included 30 patients (48 eyes) who underwent HFA 24-2 Swedish Interactive Threshold Algorithm Standard and IMOvifa™ 24plus (1-2) Ambient Interactive Zippy Estimated tests on the same day and HFA 10-2 within six months. We used Spearman's rank correlation coefficient to analyze the mean deviation (MD) and pattern standard deviation (PSD) between HFA 10-2 and IMOvifa™. The central 10-degree visual field was divided into four sectors, and concordance of visual field defects between IMOvifa™ 24plus (1-2) and HFA 10-2 was evaluated using kappa analysis. Additionally, all sectors showing a sensitivity of 0 dB on the HFA 24-2 were assessed for the presence and agreement of residual visual field in HFA 10-2 and IMOvifa™ 24plus (1-2). The MD (0.843/0.804) and PSD (0.852/0.763) of IMOvifa™ 24plus (1-2) and HFA 24-2 correlated strongly with those of HFA 10-2. Regarding the ability to detect visual field defects within the central 10 degrees, agreement with HFA 10-2 was κ = 0.715 (0.611,0.819) and 0.754 (0.654,0.854) for IMOvifa™ 24plus (1-2) and HFA 24-2, respectively. In the evaluation of residual visual field, IMOvifa™ 24plus (1-2) detected residual visual function in 100% of cases where HFA 10-2 indicated residual function. The IMOvifa™ 24plus (1-2) may have a higher ability to detect defects in certain areas of the visual field, compared with HFA 24-2, and may also detect residual visual function. However, the IMOvifa™ 24plus (1-2) is difficult to substitute for the 10-2 test, as the 10-2 test is necessary for evaluating visual field defects within the central 10 degrees.