Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Diagnostic accuracy of the 1,3-beta-d-glucan test and lactate dehydrogenase for pneumocystis pneumonia in non-HIV patients
by
Lv, Dan
, Xu, Jun
, Yu, Xuezhong
, Xiao, Meng
, Zhang, Li
, Yang, Jing
, Sun, Ruixue
, Zhu, Huadong
in
631/326
/ 631/326/2521
/ Dehydrogenase
/ Dehydrogenases
/ HIV
/ Human immunodeficiency virus
/ Humanities and Social Sciences
/ Immunocompromised hosts
/ Immunofluorescence
/ L-Lactate dehydrogenase
/ Lactic acid
/ multidisciplinary
/ Pneumonia
/ Polymerase chain reaction
/ Science
/ Science (multidisciplinary)
/ Serum levels
/ β-Glucan
2021
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Diagnostic accuracy of the 1,3-beta-d-glucan test and lactate dehydrogenase for pneumocystis pneumonia in non-HIV patients
by
Lv, Dan
, Xu, Jun
, Yu, Xuezhong
, Xiao, Meng
, Zhang, Li
, Yang, Jing
, Sun, Ruixue
, Zhu, Huadong
in
631/326
/ 631/326/2521
/ Dehydrogenase
/ Dehydrogenases
/ HIV
/ Human immunodeficiency virus
/ Humanities and Social Sciences
/ Immunocompromised hosts
/ Immunofluorescence
/ L-Lactate dehydrogenase
/ Lactic acid
/ multidisciplinary
/ Pneumonia
/ Polymerase chain reaction
/ Science
/ Science (multidisciplinary)
/ Serum levels
/ β-Glucan
2021
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Diagnostic accuracy of the 1,3-beta-d-glucan test and lactate dehydrogenase for pneumocystis pneumonia in non-HIV patients
by
Lv, Dan
, Xu, Jun
, Yu, Xuezhong
, Xiao, Meng
, Zhang, Li
, Yang, Jing
, Sun, Ruixue
, Zhu, Huadong
in
631/326
/ 631/326/2521
/ Dehydrogenase
/ Dehydrogenases
/ HIV
/ Human immunodeficiency virus
/ Humanities and Social Sciences
/ Immunocompromised hosts
/ Immunofluorescence
/ L-Lactate dehydrogenase
/ Lactic acid
/ multidisciplinary
/ Pneumonia
/ Polymerase chain reaction
/ Science
/ Science (multidisciplinary)
/ Serum levels
/ β-Glucan
2021
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Diagnostic accuracy of the 1,3-beta-d-glucan test and lactate dehydrogenase for pneumocystis pneumonia in non-HIV patients
Journal Article
Diagnostic accuracy of the 1,3-beta-d-glucan test and lactate dehydrogenase for pneumocystis pneumonia in non-HIV patients
2021
Request Book From Autostore
and Choose the Collection Method
Overview
We evaluated the serum levels of (1–3)-beta-
d
-glucan (BG) and lactate dehydrogenase (LDH) as a tool to support pneumocystis pneumonia (PCP) diagnostic procedures in non-HIV patients. We retrospectively collected non-HIV (human immunodeficiency virus) patients presenting clinical features of PCP between April 1st, 2013, and December 31st, 2018. A total of 225 included patients were tested for
Pneumocystis jirovecii
by polymerase chain reaction (PCR) and methenamine silver staining. Based on different exclusion criteria, 179 cases were included in the BG group, and 196 cases were included in the LDH group. In each group, cases with positive immunofluorescence (IF) microscopy and PCR were considered proven PCP, while cases with only positive PCR were considered probable PCP. Fifty patients with negative IF and PCR results and proven to be non-PCP infection were chosen randomly as the control group. The cut-off levels of BG and LDH to distinguish non-PCP from probable PCP were 110 pg/mL and 296 U/L with 88% sensitivity and 86% specificity, and 66% sensitivity and 88% specificity, respectively. The cut-off levels of BG and LDH to distinguish non-PCP from proven PCP were 285.8 pg/mL and 379 U/L with 92% sensitivity and 96% specificity, and 85% sensitivity and 77% specificity, respectively. The cut-off levels of BG and LDH to distinguish non-PCP from proven/probable PCP were 144.1 pg/mL and 363 U/L with 90% sensitivity, 86% specificity and 80% sensitivity, 76% specificity respectively. BG and LDH are reliable indicators for detecting
P. jirovecii
infection in HIV-uninfected immunocompromised patients.
Publisher
Nature Publishing Group UK,Nature Publishing Group,Nature Portfolio
Subject
MBRLCatalogueRelatedBooks
This website uses cookies to ensure you get the best experience on our website.