Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Quantifying heterogeneity in an animal model of acute respiratory distress syndrome, a comparison of inspired sinewave technique to computed tomography
by
Tran, Tu K.
, Federico, Formenti
, Tran, Minh C.
, Phan, Phi A.
, Bruce, Richard
, Perchiazzi, Gaetano
, Crockett, Douglas C.
, Payne, Stephen J.
, Farmery, Andrew D.
in
631/443/1784
/ 639/166/985
/ 692/699/1785/3193
/ Animal models
/ Computed tomography
/ Correlation coefficient
/ Heterogeneity
/ Humanities and Social Sciences
/ Inspired sinewave test
/ Lung heterogeneity
/ Lungs
/ multidisciplinary
/ PEEP
/ Perfusion
/ Respiratory distress syndrome
/ Science
/ Science (multidisciplinary)
/ Tomography
/ Ventilation
2024
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Quantifying heterogeneity in an animal model of acute respiratory distress syndrome, a comparison of inspired sinewave technique to computed tomography
by
Tran, Tu K.
, Federico, Formenti
, Tran, Minh C.
, Phan, Phi A.
, Bruce, Richard
, Perchiazzi, Gaetano
, Crockett, Douglas C.
, Payne, Stephen J.
, Farmery, Andrew D.
in
631/443/1784
/ 639/166/985
/ 692/699/1785/3193
/ Animal models
/ Computed tomography
/ Correlation coefficient
/ Heterogeneity
/ Humanities and Social Sciences
/ Inspired sinewave test
/ Lung heterogeneity
/ Lungs
/ multidisciplinary
/ PEEP
/ Perfusion
/ Respiratory distress syndrome
/ Science
/ Science (multidisciplinary)
/ Tomography
/ Ventilation
2024
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Quantifying heterogeneity in an animal model of acute respiratory distress syndrome, a comparison of inspired sinewave technique to computed tomography
by
Tran, Tu K.
, Federico, Formenti
, Tran, Minh C.
, Phan, Phi A.
, Bruce, Richard
, Perchiazzi, Gaetano
, Crockett, Douglas C.
, Payne, Stephen J.
, Farmery, Andrew D.
in
631/443/1784
/ 639/166/985
/ 692/699/1785/3193
/ Animal models
/ Computed tomography
/ Correlation coefficient
/ Heterogeneity
/ Humanities and Social Sciences
/ Inspired sinewave test
/ Lung heterogeneity
/ Lungs
/ multidisciplinary
/ PEEP
/ Perfusion
/ Respiratory distress syndrome
/ Science
/ Science (multidisciplinary)
/ Tomography
/ Ventilation
2024
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Quantifying heterogeneity in an animal model of acute respiratory distress syndrome, a comparison of inspired sinewave technique to computed tomography
Journal Article
Quantifying heterogeneity in an animal model of acute respiratory distress syndrome, a comparison of inspired sinewave technique to computed tomography
2024
Request Book From Autostore
and Choose the Collection Method
Overview
The inspired sinewave technique (IST) is a non-invasive method to measure lung heterogeneity indices (including both uneven ventilation and perfusion or heterogeneity), which reveal multiple conditions of the lung and lung injury. To evaluate the reproducibility and predicted clinical outcomes of IST heterogeneity values, a comparison with a quantitative lung computed tomography (CT) scan is performed. Six anaesthetised pigs were studied after surfactant depletion by saline-lavage. Paired measurements of lung heterogeneity were then taken with both the IST and CT. Lung heterogeneity measured by the IST was calculated by (a) the ratio of tracer gas outputs measured at oscillation periods of 180 s and 60 s, and (b) by the standard deviation of the modelled log-normal distribution of ventilations and perfusions in the simulation lung. In the CT images, lungs were manually segmented and divided into different regions according to voxel density. A quantitative CT method to calculate the heterogeneity (the Cressoni method) was applied. The IST and CT show good Pearson correlation coefficients in lung heterogeneity measurements (ventilation: 0.71, and perfusion, 0.60,
p
< 0.001). Within individual animals, the coefficients of determination average ventilation (R
2
= 0.53) and perfusion (R
2
= 0.68) heterogeneity. Strong concordance rates of 98% in ventilation and 89% when the heterogeneity changes were reported in pairs measured by CT scanning and IST methods. This quantitative method to identify heterogeneity has the potential to replicate CT lung heterogeneity, and to aid individualised care in ARDS.
Publisher
Nature Publishing Group UK,Nature Publishing Group,Nature Portfolio
Subject
This website uses cookies to ensure you get the best experience on our website.