Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
CyberKnife Xsight versus fiducial-based target-tracking: a novel 3D dosimetric comparison in a dynamic phantom
by
Grogan, Garry
, Geraghty, John
, Brown, Alan
, Scott, Alison J. D.
, Klein, Thomas J.
, Gill, Suki
, Ebert, Martin A.
, Rowshanfarzad, Pejman
, Smith, Warwick
, Alkhatib, Zaid
in
3D Dosimetry
/ Accuracy
/ Algorithms
/ Biomedical and Life Sciences
/ Biomedicine
/ Cancer Research
/ Care and treatment
/ CyberKnife
/ Dosimeters
/ Dosimetry
/ Imaging
/ Invasiveness
/ Lung cancer
/ Lung cancer, Non-small cell
/ Methods
/ Non-small cell lung carcinoma
/ Oncology
/ Patients
/ Planning
/ Quasars
/ Radiation dosimetry
/ Radiology
/ Radiotherapy
/ Rotation
/ Small cell lung carcinoma
/ Tracking systems
/ Tumor-tracking
/ Xsight
2022
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
CyberKnife Xsight versus fiducial-based target-tracking: a novel 3D dosimetric comparison in a dynamic phantom
by
Grogan, Garry
, Geraghty, John
, Brown, Alan
, Scott, Alison J. D.
, Klein, Thomas J.
, Gill, Suki
, Ebert, Martin A.
, Rowshanfarzad, Pejman
, Smith, Warwick
, Alkhatib, Zaid
in
3D Dosimetry
/ Accuracy
/ Algorithms
/ Biomedical and Life Sciences
/ Biomedicine
/ Cancer Research
/ Care and treatment
/ CyberKnife
/ Dosimeters
/ Dosimetry
/ Imaging
/ Invasiveness
/ Lung cancer
/ Lung cancer, Non-small cell
/ Methods
/ Non-small cell lung carcinoma
/ Oncology
/ Patients
/ Planning
/ Quasars
/ Radiation dosimetry
/ Radiology
/ Radiotherapy
/ Rotation
/ Small cell lung carcinoma
/ Tracking systems
/ Tumor-tracking
/ Xsight
2022
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
CyberKnife Xsight versus fiducial-based target-tracking: a novel 3D dosimetric comparison in a dynamic phantom
by
Grogan, Garry
, Geraghty, John
, Brown, Alan
, Scott, Alison J. D.
, Klein, Thomas J.
, Gill, Suki
, Ebert, Martin A.
, Rowshanfarzad, Pejman
, Smith, Warwick
, Alkhatib, Zaid
in
3D Dosimetry
/ Accuracy
/ Algorithms
/ Biomedical and Life Sciences
/ Biomedicine
/ Cancer Research
/ Care and treatment
/ CyberKnife
/ Dosimeters
/ Dosimetry
/ Imaging
/ Invasiveness
/ Lung cancer
/ Lung cancer, Non-small cell
/ Methods
/ Non-small cell lung carcinoma
/ Oncology
/ Patients
/ Planning
/ Quasars
/ Radiation dosimetry
/ Radiology
/ Radiotherapy
/ Rotation
/ Small cell lung carcinoma
/ Tracking systems
/ Tumor-tracking
/ Xsight
2022
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
CyberKnife Xsight versus fiducial-based target-tracking: a novel 3D dosimetric comparison in a dynamic phantom
Journal Article
CyberKnife Xsight versus fiducial-based target-tracking: a novel 3D dosimetric comparison in a dynamic phantom
2022
Request Book From Autostore
and Choose the Collection Method
Overview
Background
The CyberKnife Xsight lung-tracking system (XLTS) provides an alternative to fiducial-based target-tracking systems (FTTS) for non-small-cell lung cancer (NSCLC) patients without invasive fiducial insertion procedures. This study provides a method for 3D independent dosimetric verification of the accuracy of the FTTS compared to the XLTS without relying on log-files generated by the CyberKnife system.
Methods
A respiratory motion trace was taken from a 4D-CT of a real lung cancer patient and applied to a modified QUASAR™ respiratory motion phantom. A novel approach to 3D dosimetry was developed using Gafchromic EBT3 film, allowing the 3D dose distribution delivered to the moving phantom to be reconstructed. Treatments were planned using the recommended margins for one and three fiducial markers and XLTS 2-view, 1-view and 0-view target-tracking modalities. The dose delivery accuracy was analysed by comparing the reconstructed dose distributions to the planned dose distributions using gamma index analysis.
Results
For the 3%/2 mm gamma criterion, gamma passing rates up to 99.37% were observed for the static deliveries. The 3-fiducial and 1-fiducial-based deliveries exhibited passing rates of 93.74% and 97.82%, respectively, in the absence of target rotation. When target rotation was considered, the passing rate for 1-fiducial tracking degraded to 91.24%. The passing rates observed for XLTS 2-view, 1-view and 0-view target-tracking were 92.78%, 96.22% and 76.08%, respectively.
Conclusions
Except for the XLTS 0-view, the dosimetric accuracy of the XLTS was comparable to the FTTS under equivalent treatment conditions. This study gives us further confidence in the CyberKnife XLTS and FTTS systems.
MBRLCatalogueRelatedBooks
Related Items
Related Items
This website uses cookies to ensure you get the best experience on our website.