MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Determination of aortic stiffness using 4D flow cardiovascular magnetic resonance - a population-based study
Determination of aortic stiffness using 4D flow cardiovascular magnetic resonance - a population-based study
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Determination of aortic stiffness using 4D flow cardiovascular magnetic resonance - a population-based study
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Determination of aortic stiffness using 4D flow cardiovascular magnetic resonance - a population-based study
Determination of aortic stiffness using 4D flow cardiovascular magnetic resonance - a population-based study

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Determination of aortic stiffness using 4D flow cardiovascular magnetic resonance - a population-based study
Determination of aortic stiffness using 4D flow cardiovascular magnetic resonance - a population-based study
Journal Article

Determination of aortic stiffness using 4D flow cardiovascular magnetic resonance - a population-based study

2018
Request Book From Autostore and Choose the Collection Method
Overview
Background Increased aortic stiffness is an independent predictor of cardiovascular disease. Optimal measurement is highly beneficial for the detection of atherosclerosis and the management of patients at risk. Thus, it was our purpose to selectively measure aortic stiffness using a novel imaging method and to provide reference values from a population-based study. Methods One hundred twenty six inhabitants of Freiburg, Germany, between 20 and 80 years prospectively underwent 3 Tesla cardiovascular magnetic resonance (CMR) of the thoracic aorta. 4D flow CMR (spatial/temporal resolution 2mm 3 /20ms) was executed to calculate aortic pulse wave velocity (PWV) in m/s using dedicated software. In addition, we calculated distensibility coefficients (DC) using 2D CINE CMR imaging of the ascending (AAo) and descending aorta (DAo). Segmental aortic diameter and thickness of aortic plaques were determined by 3D T1 weighted CMR (spatial resolution 1mm 3 ). Results PWV increased from 4.93 ± 0.54 m/s in 20–30 year-old to 8.06 ± 1.03 m/s in 70–80 year-old subjects. PWV was significantly lower in women compared to men ( p  < 0.0001). Increased blood pressure (systolic r  = 0.36, p  < 0.0001; diastolic r  = 0.33, p  = 0.0001; mean arterial pressure r  = 0.37, p  < 0.0001) correlated with PWV after adjustment for age and gender. Finally, PWV increased with increasing diameter of the aorta (ascending aorta r  = 0.20, p  = 0.026; aortic arch r  = 0.24, p  = 0.009; descending aorta r  = 0.26, p  = 0.004). Correlation of PWV and DC of the AAo and DAo or the mean of both was high ( r  = 0.69, r  = 0.68, r  = 0.73; p  < 0.001). Conclusions 4D flow CMR was successfully applied to calculate aortic PWV and thus aortic stiffness. Findings showed a high correlation with distensibility coefficients representing local compliance of the aorta. Our novel method and reference data for PWV may provide a reliable biomarker for the identification of patients with underlying cardiovascular disease and optimal guidance of future treatment in studies or clinical routine.