MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Relation Between Six-Minute Walk Test Performance and Outcomes After Transcatheter Aortic Valve Implantation (from the PARTNER Trial)
Relation Between Six-Minute Walk Test Performance and Outcomes After Transcatheter Aortic Valve Implantation (from the PARTNER Trial)
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Relation Between Six-Minute Walk Test Performance and Outcomes After Transcatheter Aortic Valve Implantation (from the PARTNER Trial)
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Relation Between Six-Minute Walk Test Performance and Outcomes After Transcatheter Aortic Valve Implantation (from the PARTNER Trial)
Relation Between Six-Minute Walk Test Performance and Outcomes After Transcatheter Aortic Valve Implantation (from the PARTNER Trial)

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Relation Between Six-Minute Walk Test Performance and Outcomes After Transcatheter Aortic Valve Implantation (from the PARTNER Trial)
Relation Between Six-Minute Walk Test Performance and Outcomes After Transcatheter Aortic Valve Implantation (from the PARTNER Trial)
Journal Article

Relation Between Six-Minute Walk Test Performance and Outcomes After Transcatheter Aortic Valve Implantation (from the PARTNER Trial)

2013
Request Book From Autostore and Choose the Collection Method
Overview
Functional capacity as assessed by 6-minute walk test distance (6MWTD) has been shown to predict outcomes in selected cohorts with cardiovascular disease. To evaluate the association between 6MWTD and outcomes after transcatheter aortic valve implantation (TAVI) among participants in the Placement of AoRTic TraNscathetER valve (PARTNER) trial, TAVI recipients (n = 484) were stratified into 3 groups according to baseline 6MWTD: unable to walk (n = 218), slow walkers (n = 133), in whom 6MWTD was below the median (128.5 meters), and fast walkers (n = 133) with 6MWTD >128.5 meters. After TAVI, among fast walkers, follow-up 6MWTD decreased by 44 ± 148 meters at 12 months (p <0.02 compared with baseline). In contrast, among slow walkers, 6MWTD improved after TAVI by 58 ± 126 meters (p <0.001 compared with baseline). Similarly, among those unable to walk, 6MWTD distance increased by 66 ± 109 meters (p <0.001 compared with baseline). There were no differences in 30-day outcomes among 6MWTD groups. At 2 years, the rate of death from any cause was 42.5% in those unable to walk, 31.2% in slow walkers, and 28.8% in fast walkers (p = 0.02), driven primarily by differences in noncardiac death. In conclusion, among high-risk older adults undergoing TAVI, baseline 6MWTD does not predict procedural outcomes but does predict long-term mortality. Nonetheless, patients with poor baseline functional status exhibit the greatest improvement in 6MWTD. Additional work is required to identify those with poor functional status who stand to benefit the most from TAVI.