MbrlCatalogueTitleDetail

Do you wish to reserve the book?
CFD-based design of air wall water blocking for underground garage entrances and exits
CFD-based design of air wall water blocking for underground garage entrances and exits
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
CFD-based design of air wall water blocking for underground garage entrances and exits
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
CFD-based design of air wall water blocking for underground garage entrances and exits
CFD-based design of air wall water blocking for underground garage entrances and exits

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
CFD-based design of air wall water blocking for underground garage entrances and exits
CFD-based design of air wall water blocking for underground garage entrances and exits
Journal Article

CFD-based design of air wall water blocking for underground garage entrances and exits

2025
Request Book From Autostore and Choose the Collection Method
Overview
In the increasingly perfect underground garage construction process, the underground garage entrance water blocking problem is getting more and more attention. This paper proposes a kind of air wall water-blocking device applied to underground garage. The device is installed on the side of the straight and curved paths at the entrances and exits of the spiral underground garage. It utilizes two fans to blow the water to the drain on the other side to achieve unobstructed access to stop the water. In this paper, CFD simulation is firstly carried out on the straight road of the spiral underground garage to verify the feasibility of the program. The accuracy of the simulation results was verified by building a straight road model and conducting experiments. After that, an equal-scale 3D model of the spiral underground garage was built. Orthogonal experiments on the effects of inlet water flow velocity, fan wind speed at the straight road and fan wind speed at the curved road on the water blocking effect were carried out by using CFD simulation. A preliminary range of water velocity of 2.250 m/min to 6.786 m/min was obtained experimentally, and this range of water velocity was used as an input parameter for the simulation. The results show that the speed of water flow at the entrance of the garage and the wind speed of the fan at the straight road have a greater effect on the water blocking effect than the wind speed of the fan at the curved road. When the wind speed of the fan at the straight road is 25m/s, proper adjustment of the wind speed of the fan at the curved road can realize a good water-blocking effect of the spiral underground garage entrance within the range of water flow rate of 2.250m/min ~ 6.786m/min. Therefore, in the practical application of using the air wall water blocking scheme to realize the underground garage entrance water blocking strategy is to give priority to improve the wind speed of the fan at the straight road to improve the effect of water blocking.