Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Randomized, crossover clinical trial on the safety, feasibility, and usability of the ABLE exoskeleton: A comparative study with knee-ankle-foot orthoses
by
Tolrà-Campanyà, Mariona
, Font-Llagunes, Josep M.
, Guirao-Cano, Lluis
, Pérez-Cañabate, Florentina
, Rodríguez-Fernández, Antonio
, Lobo-Prat, Joan
in
Adult
/ Adverse events
/ Ankle
/ Biology and Life Sciences
/ Care and treatment
/ Clinical trials
/ Comparative studies
/ Complications and side effects
/ Cross-Over Studies
/ Data collection
/ Diagnosis
/ Energy consumption
/ Engineering and Technology
/ Enrollments
/ Exoskeleton
/ Exoskeleton Device - adverse effects
/ Exoskeletons
/ Feasibility Studies
/ Feet
/ Female
/ Foot Orthoses - adverse effects
/ Gait
/ Gait - physiology
/ Humans
/ Knee
/ Male
/ Medical equipment
/ Medicine and Health Sciences
/ Middle Aged
/ Orthoses
/ Paralysis
/ Paraplegia
/ Paraplegics
/ Patient satisfaction
/ Rehabilitation
/ Robotics
/ Safety
/ Spinal cord injuries
/ Spinal Cord Injuries - physiopathology
/ Spinal Cord Injuries - rehabilitation
/ Standard of care
/ Therapy
/ Training
/ Usability
/ Walking
2025
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Randomized, crossover clinical trial on the safety, feasibility, and usability of the ABLE exoskeleton: A comparative study with knee-ankle-foot orthoses
by
Tolrà-Campanyà, Mariona
, Font-Llagunes, Josep M.
, Guirao-Cano, Lluis
, Pérez-Cañabate, Florentina
, Rodríguez-Fernández, Antonio
, Lobo-Prat, Joan
in
Adult
/ Adverse events
/ Ankle
/ Biology and Life Sciences
/ Care and treatment
/ Clinical trials
/ Comparative studies
/ Complications and side effects
/ Cross-Over Studies
/ Data collection
/ Diagnosis
/ Energy consumption
/ Engineering and Technology
/ Enrollments
/ Exoskeleton
/ Exoskeleton Device - adverse effects
/ Exoskeletons
/ Feasibility Studies
/ Feet
/ Female
/ Foot Orthoses - adverse effects
/ Gait
/ Gait - physiology
/ Humans
/ Knee
/ Male
/ Medical equipment
/ Medicine and Health Sciences
/ Middle Aged
/ Orthoses
/ Paralysis
/ Paraplegia
/ Paraplegics
/ Patient satisfaction
/ Rehabilitation
/ Robotics
/ Safety
/ Spinal cord injuries
/ Spinal Cord Injuries - physiopathology
/ Spinal Cord Injuries - rehabilitation
/ Standard of care
/ Therapy
/ Training
/ Usability
/ Walking
2025
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Randomized, crossover clinical trial on the safety, feasibility, and usability of the ABLE exoskeleton: A comparative study with knee-ankle-foot orthoses
by
Tolrà-Campanyà, Mariona
, Font-Llagunes, Josep M.
, Guirao-Cano, Lluis
, Pérez-Cañabate, Florentina
, Rodríguez-Fernández, Antonio
, Lobo-Prat, Joan
in
Adult
/ Adverse events
/ Ankle
/ Biology and Life Sciences
/ Care and treatment
/ Clinical trials
/ Comparative studies
/ Complications and side effects
/ Cross-Over Studies
/ Data collection
/ Diagnosis
/ Energy consumption
/ Engineering and Technology
/ Enrollments
/ Exoskeleton
/ Exoskeleton Device - adverse effects
/ Exoskeletons
/ Feasibility Studies
/ Feet
/ Female
/ Foot Orthoses - adverse effects
/ Gait
/ Gait - physiology
/ Humans
/ Knee
/ Male
/ Medical equipment
/ Medicine and Health Sciences
/ Middle Aged
/ Orthoses
/ Paralysis
/ Paraplegia
/ Paraplegics
/ Patient satisfaction
/ Rehabilitation
/ Robotics
/ Safety
/ Spinal cord injuries
/ Spinal Cord Injuries - physiopathology
/ Spinal Cord Injuries - rehabilitation
/ Standard of care
/ Therapy
/ Training
/ Usability
/ Walking
2025
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Randomized, crossover clinical trial on the safety, feasibility, and usability of the ABLE exoskeleton: A comparative study with knee-ankle-foot orthoses
Journal Article
Randomized, crossover clinical trial on the safety, feasibility, and usability of the ABLE exoskeleton: A comparative study with knee-ankle-foot orthoses
2025
Request Book From Autostore
and Choose the Collection Method
Overview
Wearable exoskeletons are emerging as a new tool for gait training. However, comparisons between exoskeletons and conventional orthoses in terms of safety and feasibility are scarce. This study assessed the safety, feasibility, usability, and learning process of using the ABLE Exoskeleton in people with spinal cord injury (SCI) while comparing it with knee-ankle-foot orthoses (KAFOs). In this randomized, crossover clinical trial, 10 patients with chronic complete SCI (T4-T12) conducted a 10-session training and assessment protocol with each device: KAFOs and the ABLE Exoskeleton. Outcomes on safety (adverse events), and feasibility and usability (level of assistance, donning/doffing, therapy activities) were recorded for both devices. Evaluation sessions included standard clinical tests (Timed Up and Go, 10-Meter Walk Test, and 6-Minute Walk Test) to assess gait performance. The therapy metrics (number of steps, distance, gait speed, and standing and walking time) were recorded at each session for the robotic device. Participants quickly learned how to use the ABLE Exoskeleton, showing improvements in all therapy metrics (p<0.05) and the 6-Minute Walk Test (p<0.05). Participants reported less adverse events with the robotic device than KAFOs (17 and 31, respectively). Total donning and doffing time was 43 s faster with the robotic device using comparable levels of assistance. The time to complete the therapy activities was very similar between devices. Overall, participants needed 1 to 4 training sessions to perform essential therapy activities (sit/stand transitions, walking 10 meters, turning around) with both devices using minimum assistance or less. The results of this study show that it is feasible and safe for people with motor complete paraplegia due to SCI (T4-T12) to use the ABLE Exoskeleton for gait training in a rehabilitation hospital setting. The ABLE Exoskeleton proved to be as practical and easy to use as conventional orthoses, with fewer AEs reported when using the exoskeleton versus the KAFOs.
Publisher
Public Library of Science,Public Library of Science (PLoS)
Subject
/ Ankle
/ Complications and side effects
/ Exoskeleton Device - adverse effects
/ Feet
/ Female
/ Foot Orthoses - adverse effects
/ Gait
/ Humans
/ Knee
/ Male
/ Medicine and Health Sciences
/ Orthoses
/ Robotics
/ Safety
/ Spinal Cord Injuries - physiopathology
/ Spinal Cord Injuries - rehabilitation
/ Therapy
/ Training
/ Walking
This website uses cookies to ensure you get the best experience on our website.