MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Reproducibility in Echocardiographic Assessment of Diastolic Function in a Population Based Study (The STANISLAS Cohort Study)
Reproducibility in Echocardiographic Assessment of Diastolic Function in a Population Based Study (The STANISLAS Cohort Study)
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Reproducibility in Echocardiographic Assessment of Diastolic Function in a Population Based Study (The STANISLAS Cohort Study)
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Reproducibility in Echocardiographic Assessment of Diastolic Function in a Population Based Study (The STANISLAS Cohort Study)
Reproducibility in Echocardiographic Assessment of Diastolic Function in a Population Based Study (The STANISLAS Cohort Study)

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Reproducibility in Echocardiographic Assessment of Diastolic Function in a Population Based Study (The STANISLAS Cohort Study)
Reproducibility in Echocardiographic Assessment of Diastolic Function in a Population Based Study (The STANISLAS Cohort Study)
Journal Article

Reproducibility in Echocardiographic Assessment of Diastolic Function in a Population Based Study (The STANISLAS Cohort Study)

2015
Request Book From Autostore and Choose the Collection Method
Overview
There is limited evidence regarding intra-observer and inter-observer variations in echocardiographic measurements of diastolic function. This study aimed to assess this reproducibly within a population-based cohort study. Sixty subjects in sinus rhythm were randomly selected among 4th visit participants of the STANISLAS Cohort (Lorraine region, France). This 4th examination systematically included M-mode, 2-dimensional, DTI and pulsed-wave Doppler echocardiograms. Reproducibility of variables was studied by intra-class correlation coefficients (ICC) and Bland Altman plots. Our population was on average middle-aged (50 ± 14 y), overweight (BMI = 26 ± 6 kg/m2) and non-smoking (87%) with a quarter of the participants having self-declared hypertension or treated with anti-hypertensive medication(s). Intra-observer ICC were > 0.90 for all analyzed parameters except for left ventricular ejection fraction (LVEF) which was 0.89 (0.81-0.93). The mean relative intra-observer differences were small and limits of agreement of relative differences were narrow for all considered parameters (<5% and <15% respectively). Inter-observer ICC were > 0.90 for all analyzed parameters except for LVEF (ICC = 0.87) and both mitral and pulmonary A wave duration (0.83 and 0.73 respectively). The mean relative inter-observer differences were <5% for all parameters except for pulmonary A wave duration (mean difference = 6.5%). Limits of agreement of relative differences were narrow (<15%), except for mitral A wave duration and velocity (both <20%) as well as left ventricular mass and pulmonary A wave duration (both <30%). Intra-observer agreements with regard to the presence and severity of diastolic dysfunction were excellent (Kappa = 0.93 (0.83-1.00) and 0.88 (0.75-0.99), respectively). In this validation study within the STANISLAS cohort, diastolic function echocardiographic parameters were found to be highly reproducible. Diastolic dysfunction consequently appears as a highly effective clinical and research tool.