Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Field Method Comparison between Passive Air Samplers and Continuous Monitors for VOCs and NO2 in El Paso, Texas
by
Gonzales, Melissa
, Smith, Luther A.
, Mukerjee, Shaibal
, Noble, Christopher A.
, Norris, Gary A.
, Özkaynak, A. Halûk
, Neas, Lucas M.
, Morandi, Maria T.
in
Air Pollutants - analysis
/ Applied sciences
/ Automation
/ Environmental Monitoring - methods
/ Exact sciences and technology
/ Luminescent Measurements
/ Models, Statistical
/ Nitrogen Dioxide - analysis
/ Organic Chemicals - analysis
/ Pollution
/ Sensitivity and Specificity
/ Texas
2004
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Field Method Comparison between Passive Air Samplers and Continuous Monitors for VOCs and NO2 in El Paso, Texas
by
Gonzales, Melissa
, Smith, Luther A.
, Mukerjee, Shaibal
, Noble, Christopher A.
, Norris, Gary A.
, Özkaynak, A. Halûk
, Neas, Lucas M.
, Morandi, Maria T.
in
Air Pollutants - analysis
/ Applied sciences
/ Automation
/ Environmental Monitoring - methods
/ Exact sciences and technology
/ Luminescent Measurements
/ Models, Statistical
/ Nitrogen Dioxide - analysis
/ Organic Chemicals - analysis
/ Pollution
/ Sensitivity and Specificity
/ Texas
2004
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Field Method Comparison between Passive Air Samplers and Continuous Monitors for VOCs and NO2 in El Paso, Texas
by
Gonzales, Melissa
, Smith, Luther A.
, Mukerjee, Shaibal
, Noble, Christopher A.
, Norris, Gary A.
, Özkaynak, A. Halûk
, Neas, Lucas M.
, Morandi, Maria T.
in
Air Pollutants - analysis
/ Applied sciences
/ Automation
/ Environmental Monitoring - methods
/ Exact sciences and technology
/ Luminescent Measurements
/ Models, Statistical
/ Nitrogen Dioxide - analysis
/ Organic Chemicals - analysis
/ Pollution
/ Sensitivity and Specificity
/ Texas
2004
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Field Method Comparison between Passive Air Samplers and Continuous Monitors for VOCs and NO2 in El Paso, Texas
Journal Article
Field Method Comparison between Passive Air Samplers and Continuous Monitors for VOCs and NO2 in El Paso, Texas
2004
Request Book From Autostore
and Choose the Collection Method
Overview
This study evaluates the performance of Model 3300 Ogawa Passive Nitrogen Dioxide (NO
2
) Samplers and 3M 3520 Organic Vapor Monitors (OVMs) by comparing integrated passive sampling concentrations to averaged hourly NO
2
and volatile organic compound (VOC) measurements at two sites in El Paso, TX. Sampling periods were three time intervals (3-day weekend, 4-day weekday, and 7-day weekly) for three consecutive weeks. OVM concentrations were corrected for ambient pressure to account for higher elevation. Precise results (<5% relative standard deviation, RSD) were found for NO
2
measurements from collocated Ogawa samplers. Reproducibility was lower from duplicate OVMs for BTEX (benzene, toluene, ethylbenzene, and xylene isomers) VOCs (≥7% RSD for 2-day samples) with better precision for longer sampling periods. Comparison of Ogawa NO
2
samplers with chemiluminescence measurements averaged over the same time period suggested potential calibration problems with the chemiluminescence analyzer. For BTEX species, generally good agreement was obtained between OVMs and automated-gas chromatograph (auto-GC) measurements. The OVMs successfully tracked increasing levels of VOCs recorded by the auto-GCs.
Publisher
Taylor & Francis Group,Air & Waste Management Association
This website uses cookies to ensure you get the best experience on our website.