MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Ammonia Analyzer for Disease Diagnosis Applications
Ammonia Analyzer for Disease Diagnosis Applications
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Ammonia Analyzer for Disease Diagnosis Applications
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Ammonia Analyzer for Disease Diagnosis Applications
Ammonia Analyzer for Disease Diagnosis Applications

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Ammonia Analyzer for Disease Diagnosis Applications
Ammonia Analyzer for Disease Diagnosis Applications
Journal Article

Ammonia Analyzer for Disease Diagnosis Applications

2018
Request Book From Autostore and Choose the Collection Method
Overview
Many clinical diagnoses depend on the electronic equipment to detect and treat the diseases from basic illness to fatal diseases or injuries. But, most of the diagnosis techniques are invasive and cause pain or uncomfortable issues to the patients. However, the non-invasive methods, like breath exhale testing which is completely painless. In this work, we report a preliminary study of simple and compact wireless smartphone based sensing device. This device was fabricated to detect the ammonia vapor in the human exhaled breath towards diagnosing renal disease. The sensing performance of the device was tested in laboratory conditions and the obtained results are as follows. The developed device exhibited good sensing response of 584 % with response and recovery time in the order of seconds towards 50 ppm for ammonia vapor. Furthermore, ammonia sensitivity and selectivity tests are carried out for the developed breath analyzer device and the results are reported.