Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Research on factors influencing the positioning accuracy of four-quadrant detector
by
Zhang, Yanmei
, Li, Dongkang
in
Accuracy
/ Quadrants
/ Sensors
/ Signal to noise ratio
2021
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Research on factors influencing the positioning accuracy of four-quadrant detector
by
Zhang, Yanmei
, Li, Dongkang
in
Accuracy
/ Quadrants
/ Sensors
/ Signal to noise ratio
2021
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Research on factors influencing the positioning accuracy of four-quadrant detector
Journal Article
Research on factors influencing the positioning accuracy of four-quadrant detector
2021
Request Book From Autostore
and Choose the Collection Method
Overview
In order to analyze the positioning accuracy of the four-quadrant detector, this paper deeply studies the positioning principle of the four-quadrant detector, establishes the mathematical model of azimuth standard deviation based on Gaussian facula, and deeply analyzes the influence of each factor on the positioning accuracy from the three influencing factors of facula position, facula radius and signal-to-noise ratio. The results show that the positioning accuracy can be effectively improved by improving the signal-to-noise ratio, using smaller light spot and making the light spot as close to the center of the detector as possible.
Publisher
IOP Publishing
Subject
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.