Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Forensic discrimination of menstrual blood and peripheral blood using attenuated total reflectance (ATR)-Fourier transform infrared (FT-IR) spectroscopy and chemometrics
by
Rito, Chophi
, Sharma Sweety
, Singh, Rajinder
in
Accuracy
/ Assaults
/ Blood
/ Body fluids
/ Center and periphery
/ Chemometrics
/ Classification
/ Crime
/ Differentiation
/ Discriminant analysis
/ Discrimination
/ Evidence
/ False positive results
/ Forensic sciences
/ Fourier transforms
/ Infrared spectroscopy
/ Menstruation
/ Principal components analysis
/ Reflectance
/ Regression analysis
/ Sex crimes
/ Spectrum analysis
/ Substrates
/ Trauma
/ Victims
2020
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Forensic discrimination of menstrual blood and peripheral blood using attenuated total reflectance (ATR)-Fourier transform infrared (FT-IR) spectroscopy and chemometrics
by
Rito, Chophi
, Sharma Sweety
, Singh, Rajinder
in
Accuracy
/ Assaults
/ Blood
/ Body fluids
/ Center and periphery
/ Chemometrics
/ Classification
/ Crime
/ Differentiation
/ Discriminant analysis
/ Discrimination
/ Evidence
/ False positive results
/ Forensic sciences
/ Fourier transforms
/ Infrared spectroscopy
/ Menstruation
/ Principal components analysis
/ Reflectance
/ Regression analysis
/ Sex crimes
/ Spectrum analysis
/ Substrates
/ Trauma
/ Victims
2020
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Forensic discrimination of menstrual blood and peripheral blood using attenuated total reflectance (ATR)-Fourier transform infrared (FT-IR) spectroscopy and chemometrics
by
Rito, Chophi
, Sharma Sweety
, Singh, Rajinder
in
Accuracy
/ Assaults
/ Blood
/ Body fluids
/ Center and periphery
/ Chemometrics
/ Classification
/ Crime
/ Differentiation
/ Discriminant analysis
/ Discrimination
/ Evidence
/ False positive results
/ Forensic sciences
/ Fourier transforms
/ Infrared spectroscopy
/ Menstruation
/ Principal components analysis
/ Reflectance
/ Regression analysis
/ Sex crimes
/ Spectrum analysis
/ Substrates
/ Trauma
/ Victims
2020
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Forensic discrimination of menstrual blood and peripheral blood using attenuated total reflectance (ATR)-Fourier transform infrared (FT-IR) spectroscopy and chemometrics
Journal Article
Forensic discrimination of menstrual blood and peripheral blood using attenuated total reflectance (ATR)-Fourier transform infrared (FT-IR) spectroscopy and chemometrics
2020
Request Book From Autostore
and Choose the Collection Method
Overview
Body fluids are one of the most important pieces of evidence encountered in forensic cases especially in cases of sexual assault. Analysis of such evidence can help to establish a link between the perpetrator, the victim, and the crime scene and thereby assist in crime reconstruction. However, one of the biggest challenges faced by the investigators in sexual assault cases is that of ascertaining the issue of consent of the victim. In this matter, differentiation of menstrual blood (either in dried or stained form) from traumatic peripheral blood can give a potential solution on this particular aspect. A number of studies have been attempted to differentiate these two body fluids using various biochemical and serological methods. However, the methods employed are limited by factors such as sample destructivity and non-specificity, and the methods are susceptible to false positive results. In the present study, the scope of attenuated total reflectance (ATR)-Fourier transform infrared (FT-IR) spectroscopy in discriminating samples of menstrual blood and peripheral blood has been investigated, in combination with chemometric tools such as principal component analysis (PCA), partial least square regression (PLSR), and linear discriminant analysis (LDA). PCA resulted in 93.3% accuracy, whereas PLSR and LDA resulted in 100% accuracy for the discrimination of peripheral blood from menstrual blood. Application of PCA for the discrimination of menstrual blood from vaginal fluid and seminal fluid delivered 100% classification. Similarly, 100% classification was achieved while differentiating between menstrual blood and blood look-alike substances. Furthermore, in the current study, the effect of substrates on the analysis of menstrual blood has also been studied and described.
MBRLCatalogueRelatedBooks
Related Items
Related Items
We currently cannot retrieve any items related to this title. Kindly check back at a later time.
This website uses cookies to ensure you get the best experience on our website.