MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Spectroscopic and Voltammetric Analysis of Platinum Group Metals in Road Dust and Roadside Soil
Spectroscopic and Voltammetric Analysis of Platinum Group Metals in Road Dust and Roadside Soil
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Spectroscopic and Voltammetric Analysis of Platinum Group Metals in Road Dust and Roadside Soil
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Spectroscopic and Voltammetric Analysis of Platinum Group Metals in Road Dust and Roadside Soil
Spectroscopic and Voltammetric Analysis of Platinum Group Metals in Road Dust and Roadside Soil

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Spectroscopic and Voltammetric Analysis of Platinum Group Metals in Road Dust and Roadside Soil
Spectroscopic and Voltammetric Analysis of Platinum Group Metals in Road Dust and Roadside Soil
Journal Article

Spectroscopic and Voltammetric Analysis of Platinum Group Metals in Road Dust and Roadside Soil

2018
Request Book From Autostore and Choose the Collection Method
Overview
The emission of toxic compounds by increasing anthropogenic activities affects human health and the environment. Heavy road traffic and mining activities are the major anthropogenic activities contributing to the presence of metals in the environment. The release of palladium (Pd), platinum (Pt), and rhodium (Rh) into the environment increases the levels of contamination in soils, road sediments, airborne particles, and plants. These Pd, Pt, and Rh in road dusts can be soluble and enter aquatic environment posing a risk to environment and human health. The aim of this study is to determine the levels of Pd, Pt, and Rh with spectroscopy and voltammetric methods. Potential interferences by other metal ions (Na(I), Fe(III), Ni(II), Co(II)) in voltammetric methods have also been investigated in this study. At all the sampling sites very low concentrations of Pd, Pt, and Rh were found at levels that range from 0.48 ± 0.05 to 5.44 ± 0.11 ng/g (dry weight (d.wt)) for Pd(II), with 17.28 ± 3.12 to 81.44 ± 3.07 pg/g (d.wt) for Pt(II), and 14.34 ± 3.08 to 53.35 ± 4.07 pg/g (d.wt) for Rh(III). The instrumental limit of detection for Pd, Pt, and Rh for Inductively Coupled Plasma Quadrupole-based Mass Spectrometry (ICP-QMS) analysis was found to be 3 × 10−6 µg/g, 3 × 10−6 µg/g and 1 × 10−6 µg/g, respectively. In the case of voltammetric analysis the instrumental limit of detection for Pd(II), Pt(II), and Rh(III) for differential pulse adsorptive stripping voltammetry was found to be 7 × 10−8 µg/g, 6 × 10−8 µg/g, and 2 × 10−7 µg/g, respectively. For the sensor application, good precision was obtained due to consistently reproduced the measurements with a reproducibility of 6.31% for Pt(II), 7.58% for Pd(II), and 5.37% for Rh(III) (n = 10). The reproducibility for ICP-QMS analysis were 1.58% for Pd(II), 1.12% for Pt(II), and 1.37% for Rh(III) (n = 5). In the case of repeatability for differential pulse adsorptive stripping voltammetry (DPAdSV) and ICP-QMS, good standard deviations of 0.01 for Pd(II); 0.02 for Pt(II), 0.009 for Rh(III) and 0.011 for Pd, 0.019 for Pt and 0.013 for Rh, respectively.