MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Development and Application of a SWMM-Based Simulation Model for Municipal Scale Hydrologic Assessments
Development and Application of a SWMM-Based Simulation Model for Municipal Scale Hydrologic Assessments
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Development and Application of a SWMM-Based Simulation Model for Municipal Scale Hydrologic Assessments
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Development and Application of a SWMM-Based Simulation Model for Municipal Scale Hydrologic Assessments
Development and Application of a SWMM-Based Simulation Model for Municipal Scale Hydrologic Assessments

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Development and Application of a SWMM-Based Simulation Model for Municipal Scale Hydrologic Assessments
Development and Application of a SWMM-Based Simulation Model for Municipal Scale Hydrologic Assessments
Journal Article

Development and Application of a SWMM-Based Simulation Model for Municipal Scale Hydrologic Assessments

2021
Request Book From Autostore and Choose the Collection Method
Overview
There is growing interest for the installation of green stormwater infrastructure (GSI) to improve stormwater control, increase infiltration of stormwater, and improve receiving water body quality. Planning level tools are needed to inform municipal scale decisions on the type and extent of GSI to apply. Here, a modified methodology is developed for the EPA Storm Water Management Model (SWMM) to create SWMM for Low Impact Technology Evaluation (SWWM-LITE) that enables municipal scale assessment of stormwater control measure (SCM) performance with minimal input data requirements and low processing time. Hydrologic outputs of SWMM-LITE are compared to those for SWMM and the National Stormwater Calculator (SWC) to assess the performance of SWMM-LITE. Three scenarios including the baseline without SCMs and the installation of varying SCMs were investigated. Across the three scenarios, SWMM-LITE estimates of annual average hydrologic performance (runoff, infiltration, and evaporation) were within +/−0.1% of estimates from a rigorously developed SWMM model in the City of Fort Collins, CO, for an evaluation of 30 years of continuous simulation. Analysis conducted for 2 year (y), 10 y, and 100 y storm events showed less than +/−2.5% difference between SWMM and SWMM-LITE hydrologic outputs. SWC provided reasonable estimates of hydrologic parameters for the case study area, but was designed for site level analyses of performance of SCMs rather than on the municipal scale. A sensitivity analysis revealed that the most sensitive parameters were primarily consistent for the SWMM-LITE and the complete SWMM. SWMM-LITE has low input data requirements and processing time and can be applied for assessing the hydrologic performance of SCMs to inform planning level decisions.