MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Long-Term Monitoring and Statistical Analysis of Indoor Radon Concentration near the Almaty Tectonic Fault
Long-Term Monitoring and Statistical Analysis of Indoor Radon Concentration near the Almaty Tectonic Fault
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Long-Term Monitoring and Statistical Analysis of Indoor Radon Concentration near the Almaty Tectonic Fault
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Long-Term Monitoring and Statistical Analysis of Indoor Radon Concentration near the Almaty Tectonic Fault
Long-Term Monitoring and Statistical Analysis of Indoor Radon Concentration near the Almaty Tectonic Fault

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Long-Term Monitoring and Statistical Analysis of Indoor Radon Concentration near the Almaty Tectonic Fault
Long-Term Monitoring and Statistical Analysis of Indoor Radon Concentration near the Almaty Tectonic Fault
Journal Article

Long-Term Monitoring and Statistical Analysis of Indoor Radon Concentration near the Almaty Tectonic Fault

2025
Request Book From Autostore and Choose the Collection Method
Overview
This study presents the results of a spatiotemporal analysis of indoor radon concentration dynamics at the Al-Farabi Kazakh National University (Almaty, Republic of Kazakhstan), located near the Almaty tectonic fault. The research is based on a 2.5-year monitoring campaign of radon levels using the RAMON-02A radiometer. The radon activity concentration ranged from 1.29 ± 0.19 to 149 ± 22 Bq/m3. The distribution of radon concentrations was found to follow a lognormal law, with a skewness coefficient of 1.55 and kurtosis of 4.7. The mean values were 28.7 ± 4.2 Bq/m3 (arithmetic mean) and 24.5 ± 3.6 Bq/m3 (geometric mean). Distinct seasonal and monthly variations were observed: the lowest concentrations were recorded during the summer months (August—20.8 ± 3.1 Bq/m3), while the highest were observed in spring and winter (May—34.0 ± 4.9 Bq/m3, December—34.2 ± 4.9 Bq/m3). The springtime increase in radon levels is attributed to thermobaric effects, limited ventilation, and precipitation, which contributes to soil sealing. Autocorrelation analysis revealed diurnal, seasonal, and annual fluctuations, as well as quasi-periodic variations of approximately 150 days, presumably linked to geophysical processes. Correlation analysis indicated a weak positive relationship between radon concentration and air temperature during winter and spring (≈0.2), and a pronounced negative correlation with atmospheric pressure in winter (−0.57). The influence of humidity was found to be minor and seasonally variable.