MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Ground Deformation Monitoring for Subway Structure Safety Based on GNSS
Ground Deformation Monitoring for Subway Structure Safety Based on GNSS
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Ground Deformation Monitoring for Subway Structure Safety Based on GNSS
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Ground Deformation Monitoring for Subway Structure Safety Based on GNSS
Ground Deformation Monitoring for Subway Structure Safety Based on GNSS

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Ground Deformation Monitoring for Subway Structure Safety Based on GNSS
Ground Deformation Monitoring for Subway Structure Safety Based on GNSS
Journal Article

Ground Deformation Monitoring for Subway Structure Safety Based on GNSS

2023
Request Book From Autostore and Choose the Collection Method
Overview
Ground deformation poses a serious threat to the safety of subway structures. Consequently, intelligent and efficient automated safety monitoring of ground deformation along the subway has become urgent. Traditional engineering observation methods have the disadvantages of difficulties with datum selection, non-automation, and poor reliability. A ground deformation monitoring system for subway structure safety based on the Global Navigation Satellite System (GNSS) was established and validated through experimental comparisons with traditional precision leveling in this study. Based on the GNSS monitoring points, the continuous kinematic observation GNSS data of ground deformation along the subway line were obtained; a joint robust local mean decomposition (RLMD)–singular value decomposition (SVD) noise-reduction processing method for GNSS signals was proposed to realize the real-time and high-precision monitoring of ground deformation. The results show that the proposed combined noise-reduction method can reduce the maximum noise amplitude by 86%. When compared with the accuracy of the traditional precision leveling method, it was determined that the vertical positioning accuracy of the deformation monitoring system is greater than 2.7 mm, the horizontal positioning accuracy is greater than 1.3 mm, and the measurement error is less than 1.5 mm. The deformation monitoring system has the advantages of convenience, automation, and high accuracy and can be applied to ground deformation monitoring for subway structures.