MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Twelve-month efficacy and safety of glaucoma filtration device for surgery in patients with normal-tension glaucoma
Twelve-month efficacy and safety of glaucoma filtration device for surgery in patients with normal-tension glaucoma
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Twelve-month efficacy and safety of glaucoma filtration device for surgery in patients with normal-tension glaucoma
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Twelve-month efficacy and safety of glaucoma filtration device for surgery in patients with normal-tension glaucoma
Twelve-month efficacy and safety of glaucoma filtration device for surgery in patients with normal-tension glaucoma

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Twelve-month efficacy and safety of glaucoma filtration device for surgery in patients with normal-tension glaucoma
Twelve-month efficacy and safety of glaucoma filtration device for surgery in patients with normal-tension glaucoma
Journal Article

Twelve-month efficacy and safety of glaucoma filtration device for surgery in patients with normal-tension glaucoma

2019
Request Book From Autostore and Choose the Collection Method
Overview
Purpose To assess the efficacy and safety of filtration surgery using the EX-PRESS glaucoma filtration device in patients with normal-tension glaucoma (NTG). Study design Prospective, single-arm, multicenter interventional case series. Methods Eyes with NTG underwent EX-PRESS implantation with or without cataract surgery. The efficacy and safety were assessed at 1 day; 1 and 2 weeks; and 1, 3, 6, and 12 months after surgery. The main outcome measure was reduction in intraocular pressure (IOP) from baseline at 3, 6, and 12 months after surgery. Safety assessments included adverse event incidence, postoperative inflammation, and corneal endothelial cell density. Results Thirty-two Japanese patients (37 eyes) with NTG were enrolled. The mean IOP decreased from 14.8 ± 2.3 mmHg at baseline to 10.0 ± 3.1 mmHg at 12 months after surgery (mean reduction 4.9 ± 4.2 mmHg [31.1%]; P  < .0001). IOP-lowering medication use decreased from a mean of 3.3 medications per eye before surgery to 0.1 medications per eye at 12 months after surgery. IOP reductions > 20% were achieved by 61.5% of the eyes at 12 months. Adverse events were typical for filtration procedures, and none was deemed device-related. Postoperative inflammation was mild and self-limiting. The mean corneal endothelial cell density had decreased by 3.3% at 12 months after surgery. Conclusion The EX-PRESS glaucoma filtration device is safe and effective for filtration surgery in patients with NTG, providing mean IOP reduction consistent with recommendations based on the Collaborative NTG Study.