MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Right ventriculography improves the accuracy of leadless pacemaker implantation in right ventricular mid-septum
Right ventriculography improves the accuracy of leadless pacemaker implantation in right ventricular mid-septum
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Right ventriculography improves the accuracy of leadless pacemaker implantation in right ventricular mid-septum
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Right ventriculography improves the accuracy of leadless pacemaker implantation in right ventricular mid-septum
Right ventriculography improves the accuracy of leadless pacemaker implantation in right ventricular mid-septum

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Right ventriculography improves the accuracy of leadless pacemaker implantation in right ventricular mid-septum
Right ventriculography improves the accuracy of leadless pacemaker implantation in right ventricular mid-septum
Journal Article

Right ventriculography improves the accuracy of leadless pacemaker implantation in right ventricular mid-septum

2023
Request Book From Autostore and Choose the Collection Method
Overview
Background Implanting leadless pacemakers in the right ventricular (RV) apex is prone to causing pericardial tamponade and myocardial perforation. Objective To investigate the feasibility and safety of right ventriculography-guided implantation of Micra™ leadless pacemaker (Micra™, Medtronic, Minneapolis, MN, USA) in the RV mid-septum. Methods One hundred eight consecutive patients who underwent Micra™ implantation intended in the mid-septum were enrolled and randomized (3:1) into the radiography group ( n  = 81) with assistance of right ventriculography to illustrate the RV septum and the non-radiography group ( n  = 27). All subjects underwent a postoperative computed tomography (CT) scan to determine the Micra™ location. The Micra™ location assessed by CT image was compared between the two groups to confirm the accuracy of the intended pacing site. The duration of the procedure, X-ray radiation dose, and time were also compared between the two groups. Results Reconstructed CT 3-D cardiac images found the Micra™ location in the intended mid-septum in 13 patients (48.1%, 13/27) in the non-radiography group and 76 patients (93.8%, 76/81) in the radiography group ( P  < 0.0001 between two groups). There was no significant difference in procedure interval between the two groups while the X-ray radiation dose (564.86 ± 112.44 vs. 825.85 ± 156.12 mGy, P  < 0.0001), X-ray exposure time (7.79 ± 1.43 vs. 12.03 ± 2.86 min, P  < 0.0001), and the number of fluoroscopy re-positioning (2.79 ± 1.03 vs. 6.41 ± 1.82, P  < 0.0001) were significantly less in the radiography group than in the non-radiography group. No implantation-related complications were observed in both groups. Conclusion Right ventriculography increases the accuracy of Micra™ implantation in the mid-septum and reduces X-ray exposure. Trial registration The trial registration number (ChiCTR2100051374) and date (09/22/2021).