MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Improving Measurement Range of a Swellable Polymer-Clad Plastic Fiber Optic Humidity Sensor by Dye Addition
Improving Measurement Range of a Swellable Polymer-Clad Plastic Fiber Optic Humidity Sensor by Dye Addition
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Improving Measurement Range of a Swellable Polymer-Clad Plastic Fiber Optic Humidity Sensor by Dye Addition
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Improving Measurement Range of a Swellable Polymer-Clad Plastic Fiber Optic Humidity Sensor by Dye Addition
Improving Measurement Range of a Swellable Polymer-Clad Plastic Fiber Optic Humidity Sensor by Dye Addition

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Improving Measurement Range of a Swellable Polymer-Clad Plastic Fiber Optic Humidity Sensor by Dye Addition
Improving Measurement Range of a Swellable Polymer-Clad Plastic Fiber Optic Humidity Sensor by Dye Addition
Journal Article

Improving Measurement Range of a Swellable Polymer-Clad Plastic Fiber Optic Humidity Sensor by Dye Addition

2022
Request Book From Autostore and Choose the Collection Method
Overview
Humidity measurement is required in various fields. We previously developed a sensor that leverages the sudden change in the transmitted light intensity when switching from leakage mode to waveguide mode. By adjusting the low-refractive-index polymer of the cladding, we achieved measurements at 60% RH. However, for practical use, measurements at low humidity are essential. Therefore, in this study, we developed a sensor using a leakage mode that enables measurements at low humidity. To measure the leakage mode, it is necessary to increase the absorbance of the cladding and the incident angle at the core–cladding interface. Therefore, we developed a sensor in which the core was stretched, and the cladding was doped with a high concentration of dye. The experimental results confirmed that a sensor with a polymer concentration of 4% and a dye concentration of 3% could measure from 0% RH to 95% RH. The sensitivity was 0.1 dB/% RH from 0% RH to 70% RH and 0.32 dB/% RH from 70% RH to 95% RH. The estimated response time for a change from 10% to 90% light transmission for a sensor with 4% polymer concentration and 0.5% dye concentration was 22 s from 45% RH to 0% RH and 50 s from 0% RH to 45% RH.