MbrlCatalogueTitleDetail

Do you wish to reserve the book?
A preliminary exploration of establishing a mice model of hypoxic training
A preliminary exploration of establishing a mice model of hypoxic training
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
A preliminary exploration of establishing a mice model of hypoxic training
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
A preliminary exploration of establishing a mice model of hypoxic training
A preliminary exploration of establishing a mice model of hypoxic training

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
A preliminary exploration of establishing a mice model of hypoxic training
A preliminary exploration of establishing a mice model of hypoxic training
Journal Article

A preliminary exploration of establishing a mice model of hypoxic training

2025
Request Book From Autostore and Choose the Collection Method
Overview
Altitude training has been widely adopted. This study aimed to establish a mice model to determine the time point for achieving the best endurance at the lowland. C57BL/6 and BALB/c male mice were used to establish a mice model of hypoxic training with normoxic training mice, hypoxic mice, and normoxic mice as controls. All hypoxic mice were placed in a chamber filled with 16% O 2 and N 2 , and hypoxic training mice were trained for two weeks. Then mice were removed from the chamber and tested at normoxic conditions weekly at the beginning of the experiment and the second, third, fourth, and sixth weeks. The tests for endurance ability include maximal aerobic speed (MAS), Rota-rod, and grip strength. In addition, the open field, visual cliff, and Y maze were used to test cognitive abilities. Body composition and lactic acid tolerance level were also measured. For BALB/c but not C57BL/6 mice were evaluated for effectively training. Based on the average MAS of all mice, mice successfully passed the training according to the procedure: the first week (32%MAS/10min, 48%MAS/10min, and 64%MAS/10min) and second week (40%MAS/10min, 56%MAS/10min, and 72%MAS/10min). Hypoxic training mice reached peak rotarod performance on the 7th day post-training (Test 3), with significant improvements compared to Test 1, 2, 4, and 5. At Test 3, their rotarod scores significantly differed from both H and N groups, and showing a trend towards difference from NT group. Meanwhile, hypoxic mice showed significant cognitive impairment, anxiety, depression, muscle loss, and fat gain compared with hypoxic training mice after hypoxia intervation. Two consecutive weeks of 16% O2 training followed by one week of reoxygenation may be the best for endurance competition. Thus, we think a mouse model for hypoxic training was built, with Rota-rod testing as a detection indicator. Moreover, hypoxic training may alleviate the damage of hypoxia to the body.