MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Lung-to-finger circulation time can be measured stably with high reproducibility by simple breath holding method in cardiac patients
Lung-to-finger circulation time can be measured stably with high reproducibility by simple breath holding method in cardiac patients
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Lung-to-finger circulation time can be measured stably with high reproducibility by simple breath holding method in cardiac patients
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Lung-to-finger circulation time can be measured stably with high reproducibility by simple breath holding method in cardiac patients
Lung-to-finger circulation time can be measured stably with high reproducibility by simple breath holding method in cardiac patients

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Lung-to-finger circulation time can be measured stably with high reproducibility by simple breath holding method in cardiac patients
Lung-to-finger circulation time can be measured stably with high reproducibility by simple breath holding method in cardiac patients
Journal Article

Lung-to-finger circulation time can be measured stably with high reproducibility by simple breath holding method in cardiac patients

2021
Request Book From Autostore and Choose the Collection Method
Overview
Lung to finger circulation time (LFCT) has been used to estimate cardiac function. We developed a new LFCT measurement device using a laser sensor at fingertip. We measured LFCT by measuring time from re-breathing after 20 s of breath hold to the nadir of the difference of transmitted red light and infrared light, which corresponds to percutaneous oxygen saturation. Fifty patients with heart failure were enrolled. The intrasubject stability of the measurement was assessed by the intraclass correlation coefficient (ICC). The ICC calculated from 44 cases was 0.85 (95% confidence interval: 0.77–0.91), which means to have “Excellent reliability.” By measuring twice, at least one clear LFCT value was obtained in 89.1% of patients and the overall measurability was 95.7%. We conducted all LFCT measurements safely. High ICCs were obtained even after dividing patients according to age, cardiac index (CI); 0.85 and 0.84 (≥ 75 or < 75 years group, respectively), 0.81 and 0.84 (N = 26, ≥ or < 2.2 L/min/M 2 ). These results show that our new method to measure LFCT is highly stable and feasible for any type of heart failure patients.