MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Quality of Single-Cone Obturation Using Different Sizes of Matching Gutta-Percha Points of Two Reciprocating Single-File Systems in Curved and Straight Root Canals
Quality of Single-Cone Obturation Using Different Sizes of Matching Gutta-Percha Points of Two Reciprocating Single-File Systems in Curved and Straight Root Canals
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Quality of Single-Cone Obturation Using Different Sizes of Matching Gutta-Percha Points of Two Reciprocating Single-File Systems in Curved and Straight Root Canals
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Quality of Single-Cone Obturation Using Different Sizes of Matching Gutta-Percha Points of Two Reciprocating Single-File Systems in Curved and Straight Root Canals
Quality of Single-Cone Obturation Using Different Sizes of Matching Gutta-Percha Points of Two Reciprocating Single-File Systems in Curved and Straight Root Canals

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Quality of Single-Cone Obturation Using Different Sizes of Matching Gutta-Percha Points of Two Reciprocating Single-File Systems in Curved and Straight Root Canals
Quality of Single-Cone Obturation Using Different Sizes of Matching Gutta-Percha Points of Two Reciprocating Single-File Systems in Curved and Straight Root Canals
Journal Article

Quality of Single-Cone Obturation Using Different Sizes of Matching Gutta-Percha Points of Two Reciprocating Single-File Systems in Curved and Straight Root Canals

2025
Request Book From Autostore and Choose the Collection Method
Overview
Background and Objectives: Endodontic success depends on eliminating infection and creating a durable seal to prevent recontamination. The goal of this study was to assess the impact of different ISO sizes on the obturation quality using two reciprocating single-file systems, WaveOne® Gold and Procodile®, in two different canal morphologies. Material and Methods: Overall, 140 root canals from human permanent teeth were randomly assigned to 14 groups based on selected ISO sizes and straight and curved canal curvatures, and the two file systems, WaveOne® Gold files in ISO sizes 20, 25, and 45, and Procodile® files in ISO sizes 20, 25, 40, and 45, were employed for canal preparation. These 140 canals were obturated using corresponding gutta-percha points and AH-Plus sealer and the quality of the obturation was assessed after sectioning the roots (apical, middle, coronal third) by evaluating the resulting 420 sections under a digital fluorescence microscope with regard to the proportion of gutta-percha, sealer, and unfilled areas. The results were analyzed using nonparametric tests. Results: For both systems, there was a significant difference in the percentage of gutta-percha-filled areas (PGFA, p < 0.001) and sealer-filled areas (PSFA, p < 0.001 among the different ISO sizes). However, no significant difference was observed in the percentage of unfilled areas (PUA, p = 0.354). ISO 40 demonstrated the best results, with the highest percentage of gutta-percha-filled areas (87%) and the lowest percentages of sealer-filled areas (13%) and voids (0.5%). In contrast, the lowest percentages of gutta-percha filled areas were observed in root canal fillings with ISO 20 (81%) and ISO 25 (81%). Regarding both reciprocating file system sizes, ISO 45 in WaveOne® Gold and ISO 40 in Procodile® demonstrated significantly improved (p < 0.05) filling quality, with PGFA of 85% and 87%, respectively. The differences between both systems were not significant. Conclusions: The results presented suggest that larger sizes provide better filling results, especially in the apical region. These results underline the importance of selecting appropriate preparation sizes adjusted to the initial anatomical specifications to optimize root canal obturation and ensure a high quality and durable seal.