Accuracy of Consumer Wearable Heart Rate Measurement During an Ecologically Valid 24-Hour Period: Intraindividual Validation Study
by
Allen, Nicholas B
, Nelson, Benjamin W
in
Accelerometry - instrumentation
/ Accuracy
/ Activities of Daily Living
/ Adult
/ Algorithms
/ Consumers
/ Digital health
/ Electrocardiography
/ Exercise
/ Fitness Trackers - standards
/ Fitness Trackers - statistics & numerical data
/ Heart rate
/ Heart Rate - physiology
/ Heart Rate Determination - instrumentation
/ Heart Rate Determination - methods
/ Heart Rate Determination - standards
/ Humans
/ Laboratories
/ Male
/ Methods
/ Monitoring, Physiologic - instrumentation
/ Monitoring, Physiologic - methods
/ Monitoring, Physiologic - standards
/ Original Paper
/ Physical fitness
/ Pulse oximetry
/ Sensors
/ Validation Studies as Topic
/ Validity
/ Variables
/ Wearable computers
/ Wearable Electronic Devices - standards
/ Wearable Electronic Devices - statistics & numerical data
/ Weightlifting
2019
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Accuracy of Consumer Wearable Heart Rate Measurement During an Ecologically Valid 24-Hour Period: Intraindividual Validation Study
by
Allen, Nicholas B
, Nelson, Benjamin W
in
Accelerometry - instrumentation
/ Accuracy
/ Activities of Daily Living
/ Adult
/ Algorithms
/ Consumers
/ Digital health
/ Electrocardiography
/ Exercise
/ Fitness Trackers - standards
/ Fitness Trackers - statistics & numerical data
/ Heart rate
/ Heart Rate - physiology
/ Heart Rate Determination - instrumentation
/ Heart Rate Determination - methods
/ Heart Rate Determination - standards
/ Humans
/ Laboratories
/ Male
/ Methods
/ Monitoring, Physiologic - instrumentation
/ Monitoring, Physiologic - methods
/ Monitoring, Physiologic - standards
/ Original Paper
/ Physical fitness
/ Pulse oximetry
/ Sensors
/ Validation Studies as Topic
/ Validity
/ Variables
/ Wearable computers
/ Wearable Electronic Devices - standards
/ Wearable Electronic Devices - statistics & numerical data
/ Weightlifting
2019
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Accuracy of Consumer Wearable Heart Rate Measurement During an Ecologically Valid 24-Hour Period: Intraindividual Validation Study
by
Allen, Nicholas B
, Nelson, Benjamin W
in
Accelerometry - instrumentation
/ Accuracy
/ Activities of Daily Living
/ Adult
/ Algorithms
/ Consumers
/ Digital health
/ Electrocardiography
/ Exercise
/ Fitness Trackers - standards
/ Fitness Trackers - statistics & numerical data
/ Heart rate
/ Heart Rate - physiology
/ Heart Rate Determination - instrumentation
/ Heart Rate Determination - methods
/ Heart Rate Determination - standards
/ Humans
/ Laboratories
/ Male
/ Methods
/ Monitoring, Physiologic - instrumentation
/ Monitoring, Physiologic - methods
/ Monitoring, Physiologic - standards
/ Original Paper
/ Physical fitness
/ Pulse oximetry
/ Sensors
/ Validation Studies as Topic
/ Validity
/ Variables
/ Wearable computers
/ Wearable Electronic Devices - standards
/ Wearable Electronic Devices - statistics & numerical data
/ Weightlifting
2019
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Accuracy of Consumer Wearable Heart Rate Measurement During an Ecologically Valid 24-Hour Period: Intraindividual Validation Study
Journal Article
Accuracy of Consumer Wearable Heart Rate Measurement During an Ecologically Valid 24-Hour Period: Intraindividual Validation Study
2019
Request Book From Autostore
and Choose the Collection Method
Overview
Wrist-worn smart watches and fitness monitors (ie, wearables) have become widely adopted by consumers and are gaining increased attention from researchers for their potential contribution to naturalistic digital measurement of health in a scalable, mobile, and unobtrusive way. Various studies have examined the accuracy of these devices in controlled laboratory settings (eg, treadmill and stationary bike); however, no studies have investigated the heart rate accuracy of wearables during a continuous and ecologically valid 24-hour period of actual consumer device use conditions.
The aim of this study was to determine the heart rate accuracy of 2 popular wearable devices, the Apple Watch 3 and Fitbit Charge 2, as compared with the gold standard reference method, an ambulatory electrocardiogram (ECG), during consumer device use conditions in an individual. Data were collected across 5 daily conditions, including sitting, walking, running, activities of daily living (ADL; eg, chores, brushing teeth), and sleeping.
One participant, (first author; 29-year-old Caucasian male) completed a 24-hour ecologically valid protocol by wearing 2 popular wrist wearable devices (Apple Watch 3 and Fitbit Charge 2). In addition, an ambulatory ECG (Vrije Universiteit Ambulatory Monitoring System) was used as the gold standard reference method, which resulted in the collection of 102,740 individual heartbeats. A single-subject design was used to keep all variables constant except for wearable devices while providing a rapid response design to provide initial assessment of wearable accuracy for allowing the research cycle to keep pace with technological advancements. Accuracy of these devices compared with the gold standard ECG was assessed using mean error, mean absolute error, and mean absolute percent error. These data were supplemented with Bland-Altman analyses and concordance class correlation to assess agreement between devices.
The Apple Watch 3 and Fitbit Charge 2 were generally highly accurate across the 24-hour condition. Specifically, the Apple Watch 3 had a mean difference of -1.80 beats per minute (bpm), a mean absolute error percent of 5.86%, and a mean agreement of 95% when compared with the ECG across 24 hours. The Fitbit Charge 2 had a mean difference of -3.47 bpm, a mean absolute error of 5.96%, and a mean agreement of 91% when compared with the ECG across 24 hours. These findings varied by condition.
The Apple Watch 3 and the Fitbit Charge 2 provided acceptable heart rate accuracy (<±10%) across the 24 hour and during each activity, except for the Apple Watch 3 during the daily activities condition. Overall, these findings provide preliminary support that these devices appear to be useful for implementing ambulatory measurement of cardiac activity in research studies, especially those where the specific advantages of these methods (eg, scalability, low participant burden) are particularly suited to the population or research question.
Publisher
JMIR Publications
Subject
Accelerometry - instrumentation
/ Accuracy
/ Adult
/ Exercise
/ Fitness Trackers - standards
/ Fitness Trackers - statistics & numerical data
/ Heart Rate Determination - instrumentation
/ Heart Rate Determination - methods
/ Heart Rate Determination - standards
/ Humans
/ Male
/ Methods
/ Monitoring, Physiologic - instrumentation
/ Monitoring, Physiologic - methods
/ Monitoring, Physiologic - standards
/ Sensors
/ Validity
/ Wearable Electronic Devices - standards