MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Do implant angulation and print orientation compromise masked stereolithography apparatus printer model accuracy? an in-vitro study
Do implant angulation and print orientation compromise masked stereolithography apparatus printer model accuracy? an in-vitro study
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Do implant angulation and print orientation compromise masked stereolithography apparatus printer model accuracy? an in-vitro study
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Do implant angulation and print orientation compromise masked stereolithography apparatus printer model accuracy? an in-vitro study
Do implant angulation and print orientation compromise masked stereolithography apparatus printer model accuracy? an in-vitro study

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Do implant angulation and print orientation compromise masked stereolithography apparatus printer model accuracy? an in-vitro study
Do implant angulation and print orientation compromise masked stereolithography apparatus printer model accuracy? an in-vitro study
Journal Article

Do implant angulation and print orientation compromise masked stereolithography apparatus printer model accuracy? an in-vitro study

2026
Request Book From Autostore and Choose the Collection Method
Overview
Purpose The purpose of this study was to evaluate the effect of implant angle and print orientation on the accuracy of printed implant models fabricated with a masked stereolithography (mSLA) printer. Materials and methods Three digital reference models were designed in a design software (Meshmixer) with implants positioned at 0°, 10°, and 20°. Each reference design was printed at three different orientations (0°, 45°, and 90°; n  = 10) using an mSLA printer (Anycubic Photon M3 Max). Printed models were scanned using a desktop scanner (E4, 3Shape) and analyzed for linear and angular accuracy using Geomagic Control X. Statistical evaluation was performed using two-way ANOVA with Tukey’s HSD or Kruskal–Wallis with Dunn–Bonferroni correction ( p  < 0.05). Results Implant angulation and print orientation had a significant effect on linear and angular trueness of implant models ( p  < 0.05). The smallest linear deviations were obtained at 0° implant angulation and 90° print orientation. The lowest angular deviations were found at 0° print orientation. Two-way interaction was significant for linear trueness ( p  < 0.001) but not for angular trueness ( p  = 0.063). The print orientation affected both linear and angular precision. The lowest precision values were observed at 90° compared with 0° and 45° print orientations ( p  < 0.05). Conclusion The findings suggest that both implant angulation and print orientation affect the accuracy of mSLA-printed implant models. Short-span models with minimal implant angulation can be printed at 90° print orientation.