Influence of CBCT device, voxel size, and segmentation software on the accuracy of tooth volume measurements
by
Akay, Gulsun
, Ozdede, Melih
, Karadag Atas, Ozge
in
Accuracy
/ Agreements
/ Analysis
/ Calibration
/ Care and treatment
/ Computed tomography
/ Cone-beam computed tomography
/ Cone-Beam Computed Tomography - instrumentation
/ Cone-Beam Computed Tomography - statistics & numerical data
/ CT imaging
/ Dentistry
/ Diagnosis
/ Digital imaging
/ Endodontics
/ Humans
/ Image Processing, Computer-Assisted - methods
/ Image Processing, Computer-Assisted - statistics & numerical data
/ Image reconstruction
/ Imaging, Three-Dimensional - statistics & numerical data
/ Incisor - anatomy & histology
/ Incisor - diagnostic imaging
/ Incisors
/ Itk protein
/ Medicine
/ Morphology
/ Odontology
/ Odontometry - instrumentation
/ Odontometry - methods
/ Oral and Maxillofacial Surgery
/ Oral hygiene
/ Periodontal disease
/ Radiation
/ Reproducibility
/ Segmentation
/ Software
/ Statistical analysis
/ Teeth
/ Tooth
/ Tooth volume
/ Variance analysis
/ Volumetric analysis
2025
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Influence of CBCT device, voxel size, and segmentation software on the accuracy of tooth volume measurements
by
Akay, Gulsun
, Ozdede, Melih
, Karadag Atas, Ozge
in
Accuracy
/ Agreements
/ Analysis
/ Calibration
/ Care and treatment
/ Computed tomography
/ Cone-beam computed tomography
/ Cone-Beam Computed Tomography - instrumentation
/ Cone-Beam Computed Tomography - statistics & numerical data
/ CT imaging
/ Dentistry
/ Diagnosis
/ Digital imaging
/ Endodontics
/ Humans
/ Image Processing, Computer-Assisted - methods
/ Image Processing, Computer-Assisted - statistics & numerical data
/ Image reconstruction
/ Imaging, Three-Dimensional - statistics & numerical data
/ Incisor - anatomy & histology
/ Incisor - diagnostic imaging
/ Incisors
/ Itk protein
/ Medicine
/ Morphology
/ Odontology
/ Odontometry - instrumentation
/ Odontometry - methods
/ Oral and Maxillofacial Surgery
/ Oral hygiene
/ Periodontal disease
/ Radiation
/ Reproducibility
/ Segmentation
/ Software
/ Statistical analysis
/ Teeth
/ Tooth
/ Tooth volume
/ Variance analysis
/ Volumetric analysis
2025
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Influence of CBCT device, voxel size, and segmentation software on the accuracy of tooth volume measurements
by
Akay, Gulsun
, Ozdede, Melih
, Karadag Atas, Ozge
in
Accuracy
/ Agreements
/ Analysis
/ Calibration
/ Care and treatment
/ Computed tomography
/ Cone-beam computed tomography
/ Cone-Beam Computed Tomography - instrumentation
/ Cone-Beam Computed Tomography - statistics & numerical data
/ CT imaging
/ Dentistry
/ Diagnosis
/ Digital imaging
/ Endodontics
/ Humans
/ Image Processing, Computer-Assisted - methods
/ Image Processing, Computer-Assisted - statistics & numerical data
/ Image reconstruction
/ Imaging, Three-Dimensional - statistics & numerical data
/ Incisor - anatomy & histology
/ Incisor - diagnostic imaging
/ Incisors
/ Itk protein
/ Medicine
/ Morphology
/ Odontology
/ Odontometry - instrumentation
/ Odontometry - methods
/ Oral and Maxillofacial Surgery
/ Oral hygiene
/ Periodontal disease
/ Radiation
/ Reproducibility
/ Segmentation
/ Software
/ Statistical analysis
/ Teeth
/ Tooth
/ Tooth volume
/ Variance analysis
/ Volumetric analysis
2025
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Influence of CBCT device, voxel size, and segmentation software on the accuracy of tooth volume measurements
Journal Article
Influence of CBCT device, voxel size, and segmentation software on the accuracy of tooth volume measurements
2025
Request Book From Autostore
and Choose the Collection Method
Overview
Objective
This study aimed to assess the influence of cone-beam computed tomography (CBCT) device type, voxel resolution, and segmentation software on the accuracy of tooth volume measurements.
Materials and methods
Thirty extracted single-rooted human incisor teeth were included. Physical volumes were determined using the Archimedes water displacement method (WDM) as the gold standard. Each tooth was scanned using two CBCT devices (Planmeca Promax 3D-Mid and NewTom 5G-XL) at two voxel sizes (0.1-mm and 0.2-mm). Segmentation was performed using two semi-automatic software programs: 3D Slicer and ITK-SNAP. Volumetric deviations from WDM were statistically analyzed using repeated-measures ANOVA, with the significance level set at
p
< 0.05.
Results
Although the differences between the two CBCT devices (
p
= 0.431) and voxel sizes (
p
= 0.070) were not statistically significant, a trend toward improved volumetric accuracy was noted with the Planmeca Promax 3D-Mid device and the 0.1 mm voxel size. In contrast, a statistically significant difference was found between the segmentation programs (
p
< 0.001). ITK-SNAP consistently produced higher volume deviations compared to both 3D Slicer and the gold-standard WDM. The most accurate results were achieved using the Planmeca Promax 3D-Mid device, a 0.1 mm voxel size, and the 3D Slicer software, with no statistically significant deviation from WDM (
p
= 0.467).
Conclusion
CBCT device selection and voxel size (0.1-mm vs. 0.2-mm) did not significantly affect volumetric accuracy in single-rooted incisor teeth. However, the choice of segmentation software played a critical role, with 3D Slicer providing measurements closest to the gold standard. These findings highlight the importance of software selection in CBCT-based volumetric measurements for dental applications, though the results may be limited to teeth with similar anatomical complexity (e.g., single-rooted incisors).
Publisher
BioMed Central,BioMed Central Ltd,Springer Nature B.V,BMC
Subject
/ Analysis
/ Cone-beam computed tomography
/ Cone-Beam Computed Tomography - instrumentation
/ Cone-Beam Computed Tomography - statistics & numerical data
/ Humans
/ Image Processing, Computer-Assisted - methods
/ Image Processing, Computer-Assisted - statistics & numerical data
/ Imaging, Three-Dimensional - statistics & numerical data
/ Incisor - anatomy & histology
/ Incisor - diagnostic imaging
/ Incisors
/ Medicine
/ Odontometry - instrumentation
/ Oral and Maxillofacial Surgery
/ Software
/ Teeth
/ Tooth
This website uses cookies to ensure you get the best experience on our website.