The density–salinity relation of standard seawater
by
Seitz, Steffen
, Schmidt, Hannes
, Hassel, Egon
, Wolf, Henning
in
Accuracy
/ Analysis
/ Change detection
/ Chemical analysis
/ Chemical composition
/ Composition
/ Corrections
/ Density
/ Density corrections
/ Density measurement
/ Electrical conductivity
/ Electrical resistivity
/ Equations of state
/ Herbivores
/ Mathematical analysis
/ Mathematical models
/ Measurement
/ Salinity
/ Salinity effects
/ Salinometers
/ Seawater
/ Seawater composition
/ Seawater density
/ Stability
/ Standard sea water
/ Uncertainty
/ Water analysis
2018
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
The density–salinity relation of standard seawater
by
Seitz, Steffen
, Schmidt, Hannes
, Hassel, Egon
, Wolf, Henning
in
Accuracy
/ Analysis
/ Change detection
/ Chemical analysis
/ Chemical composition
/ Composition
/ Corrections
/ Density
/ Density corrections
/ Density measurement
/ Electrical conductivity
/ Electrical resistivity
/ Equations of state
/ Herbivores
/ Mathematical analysis
/ Mathematical models
/ Measurement
/ Salinity
/ Salinity effects
/ Salinometers
/ Seawater
/ Seawater composition
/ Seawater density
/ Stability
/ Standard sea water
/ Uncertainty
/ Water analysis
2018
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
The density–salinity relation of standard seawater
by
Seitz, Steffen
, Schmidt, Hannes
, Hassel, Egon
, Wolf, Henning
in
Accuracy
/ Analysis
/ Change detection
/ Chemical analysis
/ Chemical composition
/ Composition
/ Corrections
/ Density
/ Density corrections
/ Density measurement
/ Electrical conductivity
/ Electrical resistivity
/ Equations of state
/ Herbivores
/ Mathematical analysis
/ Mathematical models
/ Measurement
/ Salinity
/ Salinity effects
/ Salinometers
/ Seawater
/ Seawater composition
/ Seawater density
/ Stability
/ Standard sea water
/ Uncertainty
/ Water analysis
2018
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Journal Article
The density–salinity relation of standard seawater
2018
Request Book From Autostore
and Choose the Collection Method
Overview
The determination of salinity by means of electrical conductivity relies on stable salt proportions in the North Atlantic Ocean, because standard seawater, which is required for salinometer calibration, is produced from water of the North Atlantic. To verify the long-term stability of the standard seawater composition, it was proposed to perform measurements of the standard seawater density. Since the density is sensitive to all salt components, a density measurement can detect any change in the composition. A conversion of the density values to salinity can be performed by means of a density–salinity relation. To use such a relation with a target uncertainty in salinity comparable to that in salinity obtained from conductivity measurements, a density measurement with an uncertainty of 2 g m−3 is mandatory. We present a new density–salinity relation based on such accurate density measurements. The substitution measurement method used is described and density corrections for uniform isotopic and chemical compositions are reported. The comparison of densities calculated using the new relation with those calculated using the present reference equations of state TEOS-10 suggests that the density accuracy of TEOS-10 (as well as that of EOS-80) has been overestimated, as the accuracy of some of its underlying density measurements had been overestimated. The new density–salinity relation may be used to verify the stable composition of standard seawater by means of routine density measurements.