Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
A Novel Non-contact Heart Rate Monitor Using Impulse-Radio Ultra-Wideband (IR-UWB) Radar Technology
by
Park, Hyun-Kyung
, Park, Jun-Young
, Lee, Yonggu
, Lim, Young-Hyo
, Choi, Yeon-Woo
, Cho, Seok-Hyun
, Cho, Sung Ho
in
639/166/985
/ 692/4019/2773
/ 692/700/139/1735
/ 9/10
/ Adult
/ Aged
/ Aged, 80 and over
/ Automobile industry
/ Automobile safety
/ Correlation coefficient
/ Data acquisition
/ EKG
/ Electrocardiography
/ Female
/ Fibrillation
/ Heart rate
/ Heart Rate Determination - instrumentation
/ Heart Rate Determination - methods
/ Humanities and Social Sciences
/ Humans
/ Male
/ Middle Aged
/ multidisciplinary
/ Radar
/ Radar - instrumentation
/ Radio Waves
/ Science
/ Science (multidisciplinary)
/ Sensors
/ Signal processing
/ Young Adult
2018
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
A Novel Non-contact Heart Rate Monitor Using Impulse-Radio Ultra-Wideband (IR-UWB) Radar Technology
by
Park, Hyun-Kyung
, Park, Jun-Young
, Lee, Yonggu
, Lim, Young-Hyo
, Choi, Yeon-Woo
, Cho, Seok-Hyun
, Cho, Sung Ho
in
639/166/985
/ 692/4019/2773
/ 692/700/139/1735
/ 9/10
/ Adult
/ Aged
/ Aged, 80 and over
/ Automobile industry
/ Automobile safety
/ Correlation coefficient
/ Data acquisition
/ EKG
/ Electrocardiography
/ Female
/ Fibrillation
/ Heart rate
/ Heart Rate Determination - instrumentation
/ Heart Rate Determination - methods
/ Humanities and Social Sciences
/ Humans
/ Male
/ Middle Aged
/ multidisciplinary
/ Radar
/ Radar - instrumentation
/ Radio Waves
/ Science
/ Science (multidisciplinary)
/ Sensors
/ Signal processing
/ Young Adult
2018
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
A Novel Non-contact Heart Rate Monitor Using Impulse-Radio Ultra-Wideband (IR-UWB) Radar Technology
by
Park, Hyun-Kyung
, Park, Jun-Young
, Lee, Yonggu
, Lim, Young-Hyo
, Choi, Yeon-Woo
, Cho, Seok-Hyun
, Cho, Sung Ho
in
639/166/985
/ 692/4019/2773
/ 692/700/139/1735
/ 9/10
/ Adult
/ Aged
/ Aged, 80 and over
/ Automobile industry
/ Automobile safety
/ Correlation coefficient
/ Data acquisition
/ EKG
/ Electrocardiography
/ Female
/ Fibrillation
/ Heart rate
/ Heart Rate Determination - instrumentation
/ Heart Rate Determination - methods
/ Humanities and Social Sciences
/ Humans
/ Male
/ Middle Aged
/ multidisciplinary
/ Radar
/ Radar - instrumentation
/ Radio Waves
/ Science
/ Science (multidisciplinary)
/ Sensors
/ Signal processing
/ Young Adult
2018
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
A Novel Non-contact Heart Rate Monitor Using Impulse-Radio Ultra-Wideband (IR-UWB) Radar Technology
Journal Article
A Novel Non-contact Heart Rate Monitor Using Impulse-Radio Ultra-Wideband (IR-UWB) Radar Technology
2018
Request Book From Autostore
and Choose the Collection Method
Overview
We discovered that impulse-radio ultra-wideband (IR-UWB) radar could recognize cardiac motions in a non-contact fashion. Therefore, we measured the heart rate (HR) and rhythms using an IR-UWB radar sensor and evaluated the validity and reliability of the measurements in comparison to electrocardiography. The heart beats were measured in 6 healthy volunteers (18 samples) with normal sinus rhythm (NSR) and 16 patients (36 samples) with atrial fibrillation (AF) using both an IR-UWB radar sensor and electrocardiography simultaneously. The participants hold their breath for 20 seconds during the data acquisition. In subjects with NSR, there was excellent agreement of HR (intraclass correlation coefficient [ICC] 0.856), average R-R interval (ICC 0.997) and individual R-R intervals between the two methods (ICC 0.803). In subjects with AF, HR (ICC 0.871) and average R-R interval (ICC 0.925) from the radar sensor also agreed well with those from electrocardiography, though there was a small disagreement in the individual R-R intervals between the two methods (ICC 0.697). The rhythms computed by the signal-processing algorithm showed good agreement between the two methods (Cohen’s Kappa 0.922). The IR-UWB radar sensor is precise and accurate for assessing HR and rhythms in a non-contact fashion.
Publisher
Nature Publishing Group UK,Nature Publishing Group,Nature Portfolio
Subject
MBRLCatalogueRelatedBooks
Related Items
Related Items
This website uses cookies to ensure you get the best experience on our website.