MbrlCatalogueTitleDetail

Do you wish to reserve the book?
White noise’s effect on premature infants’ physiological parameters during peripheral intravenous catheter insertion
White noise’s effect on premature infants’ physiological parameters during peripheral intravenous catheter insertion
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
White noise’s effect on premature infants’ physiological parameters during peripheral intravenous catheter insertion
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
White noise’s effect on premature infants’ physiological parameters during peripheral intravenous catheter insertion
White noise’s effect on premature infants’ physiological parameters during peripheral intravenous catheter insertion

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
White noise’s effect on premature infants’ physiological parameters during peripheral intravenous catheter insertion
White noise’s effect on premature infants’ physiological parameters during peripheral intravenous catheter insertion
Journal Article

White noise’s effect on premature infants’ physiological parameters during peripheral intravenous catheter insertion

2025
Request Book From Autostore and Choose the Collection Method
Overview
Background Early and continuous exposure to painful stimuli in premature infants leads to short-and long-term complications. Listening to white noise is an accessible and inexpensive non-invasive method that can be used as a safe nursing intervention in hospitals. This study aimed to assess white noise’s effect on premature Infants’ physiological parameters during peripheral intravenous catheter insertion. Methods The present experimental study was conducted on 40 premature Infants. From 5 min before Indwelling catheters to 10 min after, white noise was played through headphones to infants at a controlled volume in the test group. Using a monitor, physiological parameters were recorded from 10 min before to 30 min after the Indwelling catheter. Statistical analysis was done through the SPSS version 27 software program. Results Regarding respiratory rate, there was no statistically significant difference between the two groups in the first, second, and sixth stages ( p  < 0.05). However, in the third, fourth, and fifth stages, RR in the control group was significantly higher than the test group ( p  ≤ 0.05). In terms of mean arterial blood pressure, there was no statistically significant difference between the two groups in any of the stages ( p  < 0.05). In terms of heart rate, there was no statistically significant difference between the two groups in the first, second, and sixth stages ( p  < 0.05). However, in the third, fourth, and fifth stages, HR in the control group was significantly higher than the test group ( p  ≤ 0.05). Regarding oxygen saturation percentage, there was no statistically significant difference between the two groups in the first, second, third, and sixth stages ( p  < 0.05). In contrast, in the fourth and fifth stages, the oxygen saturation percentage in the test group was significantly higher than in the control group ( p  < 0.05). Conclusions Although in both groups the painful procedure led to an increase in physiological variables (respiratory rate, heart rate, mean arterial blood pressure) and a decrease in blood oxygen saturation, in the test group these variables approached their initial state more quickly within half an hour after exposure to white noise. This confirms that the effect of white noise on the improvement of physiological variables is gradual. Clinical trial number Not applicable.