MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Optimized electroencephalogram and functional near-infrared spectroscopy-based mental workload detection method for practical applications
Optimized electroencephalogram and functional near-infrared spectroscopy-based mental workload detection method for practical applications
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Optimized electroencephalogram and functional near-infrared spectroscopy-based mental workload detection method for practical applications
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Optimized electroencephalogram and functional near-infrared spectroscopy-based mental workload detection method for practical applications
Optimized electroencephalogram and functional near-infrared spectroscopy-based mental workload detection method for practical applications

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Optimized electroencephalogram and functional near-infrared spectroscopy-based mental workload detection method for practical applications
Optimized electroencephalogram and functional near-infrared spectroscopy-based mental workload detection method for practical applications
Journal Article

Optimized electroencephalogram and functional near-infrared spectroscopy-based mental workload detection method for practical applications

2022
Request Book From Autostore and Choose the Collection Method
Overview
Background Mental workload is a critical consideration in complex man–machine systems design. Among various mental workload detection techniques, multimodal detection techniques integrating electroencephalogram (EEG) and functional near-infrared spectroscopy (fNIRS) signals have attracted considerable attention. However, existing EEG–fNIRS-based mental workload detection methods have certain defects, such as complex signal acquisition channels and low detection accuracy, which restrict their practical application. Methods The signal acquisition configuration was optimized by analyzing the feature importance in mental workload recognition model and a more accurate and convenient EEG–fNIRS-based mental workload detection method was constructed. A classical Multi-Task Attribute Battery (MATB) task was conducted with 20 participating volunteers. Subjective scale data, 64-channel EEG data, and two-channel fNIRS data were collected. Results A higher number of EEG channels correspond to higher detection accuracy. However, there is no obvious improvement in accuracy once the number of EEG channels reaches 26, with a four-level mental workload detection accuracy of 76.25 ± 5.21%. Partial results of physiological analysis verify the results of previous studies, such as that the θ power of EEG and concentration of O 2 Hb in the prefrontal region increase while the concentration of HHb decreases with task difficulty. It was further observed, for the first time, that the energy of each band of EEG signals was significantly different in the occipital lobe region, and the power of β 1 and β 2 bands in the occipital region increased significantly with task difficulty. The changing range and the mean amplitude of O 2 Hb in high-difficulty tasks were significantly higher compared with those in low-difficulty tasks. Conclusions The channel configuration of EEG–fNIRS-based mental workload detection was optimized to 26 EEG channels and two frontal fNIRS channels. A four-level mental workload detection accuracy of 76.25 ± 5.21% was obtained, which is higher than previously reported results. The proposed configuration can promote the application of mental workload detection technology in military, driving, and other complex human–computer interaction systems.