MbrlCatalogueTitleDetail

Do you wish to reserve the book?
Clinical effects of laser-based cavity preparation on class V resin-composite fillings
Clinical effects of laser-based cavity preparation on class V resin-composite fillings
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Clinical effects of laser-based cavity preparation on class V resin-composite fillings
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Clinical effects of laser-based cavity preparation on class V resin-composite fillings
Clinical effects of laser-based cavity preparation on class V resin-composite fillings

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Clinical effects of laser-based cavity preparation on class V resin-composite fillings
Clinical effects of laser-based cavity preparation on class V resin-composite fillings
Journal Article

Clinical effects of laser-based cavity preparation on class V resin-composite fillings

2022
Request Book From Autostore and Choose the Collection Method
Overview
The aim of the present clinically controlled two-year study was to investigate the influence of laser-based cavity preparation on the long-term performance of Class V resin-composite fillings. Class V non-carious lesions (n = 75) were randomly assigned to two test and one control group. Cavities in both test groups were prepared using an Er,Cr:YSGG laser (Waterlase MD, Biolase, Irvine, California, USA). The device was operated at 3 W (150 mJ, 30 J/cm 2 ), 50% water, 60% air, 30 Hz in H mode. Subsequently, laser-prepared tooth surfaces in test group I (n = 21) were additionally conditioned by acid etching (etch-and-rinse). Laser-prepared cavities of test group II (n = 21) received no additional acid conditioning. After application of an adhesive, all cavities were restored using the resin-composite Venus®. For cavities in the control group (n = 33) conventional diamond burs were used for preparation which was followed by an etch-and-rinse step, too. The fillings were evaluated immediately (baseline) and after 6, 12 and 24 months of wear according to the C-criteria of the USPHS-compatible CPM-index. The results showed that after 24 month of wear, laser-preparation was associated with fillings of high clinical acceptability. Compared to conventional bur-based treatment, laser-based cavity preparation resulted in fillings with high marginal integrity and superior marginal ledge configurations (p = 0.003). Furthermore, laser-preparation combined with additional acid-conditioning (test group I) resulted in fillings with the best marginal integrity and the lowest number in marginal discoloration, especially at the enamel-composite margins (p = 0.044). In addition, total loss of fillings was also less frequently observed in both laser groups as compared to the control. The results clearly demonstrate that laser-based cavity preparation will benefit the clinical long-time performance of Class V resin-composite fillings. Furthermore, additional acid-conditioning after laser preparation is of advantage.