Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Calibration methods for VSCs measured on AS-TD-GC-SCD
by
Le, Minh
, Stuetz, Richard
, Wang, Xinguang
in
air
/ Atmospheric Protection/Air Quality Control/Air Pollution
/ Calibration
/ Chemiluminescence
/ Chromatography, Gas
/ Correlation coefficient
/ Correlation coefficients
/ Detectors
/ Dilution
/ Dimethyl trisulfide
/ Earth and Environmental Science
/ Ecology
/ Ecotoxicology
/ Emissions
/ Environment
/ Environmental Management
/ Environmental Monitoring
/ Environmental science
/ Gas chromatography
/ Gases
/ Landfill
/ liquids
/ Luminescence
/ methanol
/ Methods
/ Monitoring/Environmental Analysis
/ Nitrogen
/ Odor thresholds
/ Odors
/ Odour
/ Pentane
/ regression analysis
/ Reproducibility of Results
/ Sample preparation
/ Sampling
/ Sampling methods
/ Sensors
/ Sewer systems
/ Sulfur
/ Sulfur - analysis
/ Sulfur compounds
/ Sulfur Compounds - analysis
/ Sulphur
/ Volatile Organic Compounds - analysis
2022
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Calibration methods for VSCs measured on AS-TD-GC-SCD
by
Le, Minh
, Stuetz, Richard
, Wang, Xinguang
in
air
/ Atmospheric Protection/Air Quality Control/Air Pollution
/ Calibration
/ Chemiluminescence
/ Chromatography, Gas
/ Correlation coefficient
/ Correlation coefficients
/ Detectors
/ Dilution
/ Dimethyl trisulfide
/ Earth and Environmental Science
/ Ecology
/ Ecotoxicology
/ Emissions
/ Environment
/ Environmental Management
/ Environmental Monitoring
/ Environmental science
/ Gas chromatography
/ Gases
/ Landfill
/ liquids
/ Luminescence
/ methanol
/ Methods
/ Monitoring/Environmental Analysis
/ Nitrogen
/ Odor thresholds
/ Odors
/ Odour
/ Pentane
/ regression analysis
/ Reproducibility of Results
/ Sample preparation
/ Sampling
/ Sampling methods
/ Sensors
/ Sewer systems
/ Sulfur
/ Sulfur - analysis
/ Sulfur compounds
/ Sulfur Compounds - analysis
/ Sulphur
/ Volatile Organic Compounds - analysis
2022
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Calibration methods for VSCs measured on AS-TD-GC-SCD
by
Le, Minh
, Stuetz, Richard
, Wang, Xinguang
in
air
/ Atmospheric Protection/Air Quality Control/Air Pollution
/ Calibration
/ Chemiluminescence
/ Chromatography, Gas
/ Correlation coefficient
/ Correlation coefficients
/ Detectors
/ Dilution
/ Dimethyl trisulfide
/ Earth and Environmental Science
/ Ecology
/ Ecotoxicology
/ Emissions
/ Environment
/ Environmental Management
/ Environmental Monitoring
/ Environmental science
/ Gas chromatography
/ Gases
/ Landfill
/ liquids
/ Luminescence
/ methanol
/ Methods
/ Monitoring/Environmental Analysis
/ Nitrogen
/ Odor thresholds
/ Odors
/ Odour
/ Pentane
/ regression analysis
/ Reproducibility of Results
/ Sample preparation
/ Sampling
/ Sampling methods
/ Sensors
/ Sewer systems
/ Sulfur
/ Sulfur - analysis
/ Sulfur compounds
/ Sulfur Compounds - analysis
/ Sulphur
/ Volatile Organic Compounds - analysis
2022
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Journal Article
Calibration methods for VSCs measured on AS-TD-GC-SCD
2022
Request Book From Autostore
and Choose the Collection Method
Overview
Volatile sulfur compounds (VSCs) are key odorous compounds from emissions of various odour sources because they are odorous and generally have very low odour threshold values. Identification and quantification of them through air server–thermal desorber–gas chromatography–sulfur chemiluminescence detector (AS-TD-GC-SCD) become more and more popular, although VSCs can be determined by other detectors. To find a valid, practical and quick calibration method is also an important step in their analytical processes. This study compared three different sample preparation and unity sampling methods using both gas standards (with 10 VSCs balanced in pure nitrogen gas) and liquid standards of 7 VSCs. For liquid standard sample preparation, two solvents (methanol and n-pentane) were tested and their calibration results were compared. The study revealed that the three calibration methods with both manual and dynamic dilution of VSC standard gases can achieve satisfactory calibration results with nice linear regression and correlation coefficient (
r
2
). The dynamic dilution and loop sampling method is recommended because of its better reliability and time-saving processing. For calibration of VSCs with liquid standards, preparing the samples using dissolved VSCs in n-pentane and analysing them using the loop sampling method achieved best calibration results. For dimethyl trisulfide (DMTS), its calibration cannot obtain as good results as other sulfur compounds even using the best performance calibration method.
Publisher
Springer International Publishing,Springer Nature B.V