MbrlCatalogueTitleDetail

Do you wish to reserve the book?
High-Density EEG Source Localisation of averaged interictal epileptic Discharges validated by surgical Outcome
High-Density EEG Source Localisation of averaged interictal epileptic Discharges validated by surgical Outcome
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
High-Density EEG Source Localisation of averaged interictal epileptic Discharges validated by surgical Outcome
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
High-Density EEG Source Localisation of averaged interictal epileptic Discharges validated by surgical Outcome
High-Density EEG Source Localisation of averaged interictal epileptic Discharges validated by surgical Outcome

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
High-Density EEG Source Localisation of averaged interictal epileptic Discharges validated by surgical Outcome
High-Density EEG Source Localisation of averaged interictal epileptic Discharges validated by surgical Outcome
Journal Article

High-Density EEG Source Localisation of averaged interictal epileptic Discharges validated by surgical Outcome

2025
Request Book From Autostore and Choose the Collection Method
Overview
Electroencephalographic source localisation (ESL) of interictal epileptiform discharges is a valuable tool for presurgical evaluation of pharmacoresistant focal epilepsy. Various forward models, inverse solutions algorithms, and software packages have been published. However, clinical validation studies are based on heterogenous end points and study cohorts. To allow comparison of different interictal ESL methods within one standardised dataset, we provide deidentified clinical data of 44 well-characterised patients with pharmacoresistant focal epilepsy and a first resective surgery, validated by 12-month postsurgical outcome. Thirty patients had favourable outcomes, including 28 with complete seizure freedom, indicating that the epileptogenic zone was correctly estimated. For each patient, pre-processed individual structural MRI, 257-channel EEG averages of homologous discharges, postsurgical structural neuroimaging, and detailed clinical and technical information are given. In patients with favourable outcomes, source maxima of averaged discharges were <10 mm remote from the resection in 67% and within a sublobe affected by the surgery in 83%. Future validation studies of new ESL approaches can be compared to this benchmark.