Asset Details
MbrlCatalogueTitleDetail
Do you wish to reserve the book?
Inter-electrode spacing of surface EMG sensors: Reduction of crosstalk contamination during voluntary contractions
by
De Luca, Carlo J.
, Gilmore, L. Donald
, Roy, Serge H.
, Kuznetsov, Mikhail
in
Adult
/ Arrays
/ Biological and medical sciences
/ Contamination
/ Crosstalk
/ Design
/ Disks
/ Electrode spacing
/ Electrodes
/ Electrodiagnosis. Electric activity recording
/ Electromyography - methods
/ EMG sensor
/ EMG signal
/ Female
/ Humans
/ Investigative techniques, diagnostic techniques (general aspects)
/ Isometric Contraction - physiology
/ Male
/ Medical sciences
/ Miscellaneous. Technology
/ Muscle Contraction - physiology
/ Muscle, Skeletal - physiology
/ Muscles
/ Muscular system
/ Physical Medicine and Rehabilitation
/ Sensors
/ Studies
/ Tibia - physiology
/ Walking
2012
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
Inter-electrode spacing of surface EMG sensors: Reduction of crosstalk contamination during voluntary contractions
by
De Luca, Carlo J.
, Gilmore, L. Donald
, Roy, Serge H.
, Kuznetsov, Mikhail
in
Adult
/ Arrays
/ Biological and medical sciences
/ Contamination
/ Crosstalk
/ Design
/ Disks
/ Electrode spacing
/ Electrodes
/ Electrodiagnosis. Electric activity recording
/ Electromyography - methods
/ EMG sensor
/ EMG signal
/ Female
/ Humans
/ Investigative techniques, diagnostic techniques (general aspects)
/ Isometric Contraction - physiology
/ Male
/ Medical sciences
/ Miscellaneous. Technology
/ Muscle Contraction - physiology
/ Muscle, Skeletal - physiology
/ Muscles
/ Muscular system
/ Physical Medicine and Rehabilitation
/ Sensors
/ Studies
/ Tibia - physiology
/ Walking
2012
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
Inter-electrode spacing of surface EMG sensors: Reduction of crosstalk contamination during voluntary contractions
by
De Luca, Carlo J.
, Gilmore, L. Donald
, Roy, Serge H.
, Kuznetsov, Mikhail
in
Adult
/ Arrays
/ Biological and medical sciences
/ Contamination
/ Crosstalk
/ Design
/ Disks
/ Electrode spacing
/ Electrodes
/ Electrodiagnosis. Electric activity recording
/ Electromyography - methods
/ EMG sensor
/ EMG signal
/ Female
/ Humans
/ Investigative techniques, diagnostic techniques (general aspects)
/ Isometric Contraction - physiology
/ Male
/ Medical sciences
/ Miscellaneous. Technology
/ Muscle Contraction - physiology
/ Muscle, Skeletal - physiology
/ Muscles
/ Muscular system
/ Physical Medicine and Rehabilitation
/ Sensors
/ Studies
/ Tibia - physiology
/ Walking
2012
Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
Inter-electrode spacing of surface EMG sensors: Reduction of crosstalk contamination during voluntary contractions
Journal Article
Inter-electrode spacing of surface EMG sensors: Reduction of crosstalk contamination during voluntary contractions
2012
Request Book From Autostore
and Choose the Collection Method
Overview
We investigated the influence of inter-electrode spacing on the degree of crosstalk contamination in surface electromyographic (sEMG) signals in the tibialis anterior (target muscle), generated by the triceps surae (crosstalk muscle), using bar and disk electrode arrays. The degree of crosstalk contamination was assessed for voluntary constant-force isometric contractions and for dynamic contractions during walking. Single-differential signals were acquired with inter-electrode spacing ranging from 5mm to 40mm. Additionally, double differential signals were acquired at 10mm spacing using the bar electrode array. Crosstalk contamination at the target muscle was expressed as the ratio of the detected crosstalk signal to that of the target muscle signal. The crosstalk contamination ratio approached a mean of 50% for the 40mm spacing for triceps surae muscle contractions at 80% MVC and tibialis anterior muscle contractions at 10% MVC. For single differential recordings, the minimum crosstalk contamination was obtained from the 10mm spacing. The results showed no significant differences between the bar and disk electrode arrays. During walking, the crosstalk contamination on the tibialis anterior muscle reached levels of 23% for a commonly used 22mm spacing single-differential disk sensor, 17% for a 10mm spacing single-differential bar sensor, and 8% for a 10mm double-differential bar sensor. For both studies the effect of electrode spacing on crosstalk contamination was statistically significant. Crosstalk contamination and inter-electrode spacing should therefore be a serious concern in gait studies when the sEMG signal is collected with single differential sensors. The contamination can distort the target muscle signal and mislead the interpretation of its activation timing and force magnitude.
Publisher
Elsevier Ltd,Elsevier,Elsevier Limited
Subject
/ Arrays
/ Biological and medical sciences
/ Design
/ Disks
/ Electrodiagnosis. Electric activity recording
/ Female
/ Humans
/ Investigative techniques, diagnostic techniques (general aspects)
/ Isometric Contraction - physiology
/ Male
/ Muscle Contraction - physiology
/ Muscle, Skeletal - physiology
/ Muscles
/ Physical Medicine and Rehabilitation
/ Sensors
/ Studies
/ Walking
This website uses cookies to ensure you get the best experience on our website.