MbrlCatalogueTitleDetail

Do you wish to reserve the book?
The accuracy of reconstruction of orbital wall fractures using prebent mesh versus patient specific implants: a randomized clinical trial
The accuracy of reconstruction of orbital wall fractures using prebent mesh versus patient specific implants: a randomized clinical trial
Hey, we have placed the reservation for you!
Hey, we have placed the reservation for you!
By the way, why not check out events that you can attend while you pick your title.
You are currently in the queue to collect this book. You will be notified once it is your turn to collect the book.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place the reservation. Kindly try again later.
Are you sure you want to remove the book from the shelf?
The accuracy of reconstruction of orbital wall fractures using prebent mesh versus patient specific implants: a randomized clinical trial
Oops! Something went wrong.
Oops! Something went wrong.
While trying to remove the title from your shelf something went wrong :( Kindly try again later!
Title added to your shelf!
Title added to your shelf!
View what I already have on My Shelf.
Oops! Something went wrong.
Oops! Something went wrong.
While trying to add the title to your shelf something went wrong :( Kindly try again later!
Do you wish to request the book?
The accuracy of reconstruction of orbital wall fractures using prebent mesh versus patient specific implants: a randomized clinical trial
The accuracy of reconstruction of orbital wall fractures using prebent mesh versus patient specific implants: a randomized clinical trial

Please be aware that the book you have requested cannot be checked out. If you would like to checkout this book, you can reserve another copy
How would you like to get it?
We have requested the book for you! Sorry the robot delivery is not available at the moment
We have requested the book for you!
We have requested the book for you!
Your request is successful and it will be processed during the Library working hours. Please check the status of your request in My Requests.
Oops! Something went wrong.
Oops! Something went wrong.
Looks like we were not able to place your request. Kindly try again later.
The accuracy of reconstruction of orbital wall fractures using prebent mesh versus patient specific implants: a randomized clinical trial
The accuracy of reconstruction of orbital wall fractures using prebent mesh versus patient specific implants: a randomized clinical trial
Journal Article

The accuracy of reconstruction of orbital wall fractures using prebent mesh versus patient specific implants: a randomized clinical trial

2025
Request Book From Autostore and Choose the Collection Method
Overview
Background Repairing fractures of the orbital wall and floor remains a complex challenge due to the intricate anatomy of the orbit and the limited visibility during surgery. With the advancement of digital technologies, tools such as DICOM (Digital Imaging and Communications in Medicine) now allow the creation of virtual mirrored models of the unaffected orbit, which can greatly assist in surgical planning and reconstruction. This study aimed to evaluate the accuracy of orbital wall reconstruction using patient-specific implants (PSIs) versus prebent titanium mesh. Materials and methods A single-blind randomized controlled clinical trial was carried out on 28 patients with unilateral orbital fractures, who were randomly divided into two equal groups. Group I underwent orbital wall reconstruction using prebent titanium mesh, while Group II received titanium PSIs. Clinical and radiographic evaluations were carried out at 1 week, 1 month, and 3 months postoperatively to evaluate enophthalmos, ocular motility, diplopia, and the precision of orbital volume restoration. Results The mean postoperative orbital volume was 27.48 ± 1.324 cm³ in Group I and 25.62 ± 1.492 cm³ in Group II. The difference in orbital volume between the reconstructed and intact orbit was significantly smaller in the PSI group (0.6543 ± 0.2767 cm³) compared to the pre-bent mesh group (1.666 ± 0.3884 cm³; p  < 0.05). Conclusion Patient-specific titanium implants significantly improved the accuracy of orbital volume restoration, particularly in cases involving large defects. Compared to pre-bent titanium mesh, PSIs reduced the need for revision surgery and offered superior volumetric outcomes. In contrast, prebent titanium mesh still provided satisfactory results for isolated single wall fractures and is likely to be cost-effective. Trial registration This trial was retrospectively registered at ClinicalTrials.gov on March 05, 2024, under the registration number NCT06294535.